NITROGEN GENERATOR AND INFLATER 95105 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. ® 3491 MISSION OAKS BLVD., CAMARILLO, CA 93011 VISIT OUR WEB SITE AT HTTP://WWW.HARBORFREIGHT.COM Copyright © 2006 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools.
SPECIFICATIONS Item Function Power Requirement Nitrogen Output Nitrogen Input Air Inlet Pressure Power Switch Power Indicator Tire Inflator Overall Dimensions Weight Description Inflates tires with nitrogen instead of air 110 VAC, 60 Hz, 234 watts 85 PSI from 3 internal tanks (50 liter total capacity) Rear connector for external tank 130 to 140 PSI Toggle: On/Off LED Lights when Power Switch is on.
Electrical Safety 4. Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators. There is an increased risk of electric shock if your body is grounded. 5. Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock. 6. Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way.
Tool Use and Care 15. Do not force the tool. Use the correct tool for your application. The correct tool will do the job better and safer at the rate for which it is designed. 16. Do not use the power tool if the Power Switch does not turn it on or off. Any tool that cannot be controlled with the Power Switch is dangerous and must be replaced. 17. Disconnect the Power Cord Plug from the power source before making any adjustments, changing accessories, or storing the tool.
4. Avoid unintentional starting. Make sure you are prepared to begin work before turning on the Nitrogen Generator and Inflater. 5. Do not force the Nitrogen Generator and Inflater. This tool will do the work better and safer at the speed and capacity for which it was designed. 6. Always unplug the Nitrogen Generator and Inflater from its electrical outlet before performing any inspection, maintenance, or cleaning procedures. 7.
Figure B Figure A Double Insulated Tools with Two Prong Plugs 4. A polarized plug (one blade is wider than the other) is used as a feature to reduce the risk of electric shock. This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do not alter the plug.” 5. Tools marked “Double Insulated” do not require grounding.
Table A RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120 VOLT) NAMEPLATE AMPERES EXTENSION CORD LENGTH (At Full Load) 25 50 75 100 150 Feet Feet Feet Feet Feet 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18 16 14 12 5.1 – 7.0 18 16 14 12 12 7.1 – 12.0 16 14 12 10 12.1 – 16.0 14 12 10 16.1 – 20.0 12 10 * Based on limiting the line voltage drop to five volts at 150% of the rated amperes.
Air Outlet Main Unit N2 Outlet Tire Inflation Unit Blue N2 Hose (505) Orange Air Hose (506) Figure C ASSEMBLY INSTRUCTIONS 1. Connect the orange Air Hose (506) to the Air Inlet (when facing fittings, viewed on left side) of the Tire Inflation Unit, and to the Main Unit Air outlet. For these steps, refer to Figures C and D. Refer to connector labels on each unit. Hose connectors snap on. 2.
OPERATING INSTRUCTIONS Controls and Indicators Air Pressure Gauge A - N2 Generation Indicator N2 Purity Analysis Display B - N2 Generation Indicator Power Indicator N2 Pressure Gauge Power Switch Figure E Inflating Tires This process extracts air from the tire and replaces it with Nitrogen. Follow these steps after the Assembly Instructions have been completed. 1. From the Tire Inflation Unit, connect the rubber hose (with tire valve clamp) to the tire air valve.
6. From the Tire Inflation Unit, turn the Converse Valve counterclockwise, and open (inline with hose) the N2 Inlet valve. • This step inflates the tire with Nitrogen. • Check the Tire Pressure Gauge on the Tire Inflation Unit, and inflate to the tire manufacturer’s recommended tire pressure. • The A or B N2 Generation Indicator will light. The N2 Pressure Gauge should read 85 PSI. • Check the N 2 Purity Analysis Display on the Main Unit. Purity should read between 95% to 99%.
INSPECTION, MAINTENANCE, AND CLEANING WARNING! Make sure the Power Switch of the NITROGEN GENERATOR AND INFLATER is in its “OFF” position and that the tool is unplugged from its electrical outlet before performing any inspection, maintenance, or cleaning procedures. 1. Before each use, inspect the general condition of the Nitrogen Generator and Inflater.
PARTS LIST NOTE: Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts.
MAIN UNIT MAJOR ASSEMBLY DRAWING SKU 95105 For technical questions, please call 1-800-444-3353 Page 13
MAIN UNIT SUBASSEMBLY DRAWINGS SKU 95105 For technical questions, please call 1-800-444-3353 Page 14
TIRE INFLATER UNIT ASSEMBLY DRAWING SKU 95105 For technical questions, please call 1-800-444-3353 Page 15
WARRANTY LIMITED 90 DAY/1 YEAR WARRANTY Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser for a period of ninety days from date of purchase that the motor, the belts (if so equipped), and the blades (if so equipped) are free of defects in materials and workmanship.