Power Supply User Manual

6800/7000 Series - Frames and Power Supplies Installation and Operation Manual 3
Frame Description Chapter 1: Introducing the 6800/7000 Series of Frames
Power and Frame Capacity
The FR-6804-1 mounting frame is identical to the FR-6804 except that it
has a GPI (General Purpose Interface) function as shown below:
The FR-6804-1 provides a GPI (General Purpose Interface)
contact closure, indicating power supply failure.
If the 6804PS(-1) is used in the FR-6804, or the 6804PS is used in
the FR-6804-1, the power supply failure indication does not
function.
Modules +ve (W) -ve (W)
Total
(W)
FR-6804(-1)
with one
6804PS-1
FR-6804(-1)
with two
6804PS-1
FR-6804(-1)
with two
6804PS -1
CF-6801
connected
FR-6804(-1)
with two
6801PS-1
and no
CF-6801
connected
FR-6801(-1)
FR-7001
FR-7000MB
ADC-6801 6.10 0.56 6.66 6 5 10 5 3 3 1
ADC-6880 1.86 1.20 3.06 10 10 10 10 4 4 1
ADM-6800 3.80 0.56 4.37 9 8 10 8 4 4 1
ADM-6804 0.50 3.93 4.43 9 7 10 8 4 4 1
AES-6880 0.70 0.24 0.94 10 10 10 10 4 4 1
ASM-6800 4.07 0.52 4.59 8 7 10 7 4 4 1
CF-6801 5W 5W 10W N/A N/A N/A N/A N/A N/A N/A
DAC-6880 2.85 0.28 3.13 10 10 10 10 4 4 1
DAR-6880 2.00 0.60 2.60 10 10 10 10 4 4 1
DEC-6801 4.15 0.33 4.48 8 7 10 6 4 4 1
DES-6801 6.46 0.49 6.95 5 5 10 4 2 - 1
DNH-6800 1.50 0.27 1.77 10 10 10 10 4 4 1
DSK-6801 11.04 0.41 11.45 3 3 6 3 - - -
EDH-6800-2 4.23 0.03 4.26 9 8 10 8 4 4 1
ENC-6801 5.90 1.40 7.30 5 4 10 6 2 2 1
ENS-6801 7.30 1.60 8.90 4 3 8 4 2 2 -
ENX-6801 5.2 1.4 6.6 6 10 6 5 4 4 1
LGI-6801 5.10 0.03 5.13 7 6 10 8 3 3 1
MXA-6801-A2-68 6.5 1.5 8 8 8 10 3 1 2 0
MXA-6801-A4-70 6.5 1.5 8 0 0 0 0 0 2 0