Power Supply User Manual

6800/7000 Series - Frames and Power Supplies Installation and Operation Manual 19
FR-6804(-1)/CF-6801 Installation Chapter 4: CF-6801 Cooling Frame
FR-6804(-1)/CF-6801 Installation
To properly install the CF-6801 with the FR-6804(-1), follow this
procedure:
1. Mount the CF-6801 directly above the FR-6804(-1).
2. Attach the DC supply cable to the DC 3-pin connector at the back of
the FR-6804(-1), following the labeled positions for positive,
negative, and ground.
3. Attach the other end of the DC supply cable to the DC 5-pin
connector at the
back of the CF-6801 cooling frame, observing
correct polarity.
See
Figure 4-3.
Figure 4-2. FR-6804(-1) and CF-6801 Connections
LEITCH
CF-6801
GND
V+
V-
GPI 1
GPI 2
MADE IN
CANADA
BLK
CLEAR
SHIELD
R
FR-6804
GND
NC
NO
GND
V+2
V-2
90-250VAC
270VA
50/60Hz
MADE IN CANADA
CAUTION: THIS EQUIPMENT HAS MORE THAN
ONE POWER SUPPLY CORD. TO REDUCE THE
RISK OF ELECTRICAL SHOCK, DISCONNECT TWO
POWER SUPPLY CORDS BEFORE SERVICING.
CLEAR
SHIELD
BLK
DC Supply Cable
(M8761 Belden
or equivalent)