Installation Guide

Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
17
Table 9
Vent Pipe & Terminal Specications for Positive-Pressure Indoor Vent Kits
Heater
Model
Hayward Kit Part
Number
Maximum
Installation
Altitude
Nominal
Vent Pipe
Diameter
Appliance Adapter Gas
Vent
Type
Vent Pipe
Horizontal Vent
Terminal
Vertical Vent
Terminal
H150FD
H200FD
UHXPOSHZ11501
UHXPOSHZ12001
10,100 ft 6 inch Included in UHX kit
NAT &
LP
Single-
Wall
Heatfab Saf-T Vent EZ Seal
P/N 960x *
Heatfab P/N
9614TERM
Heatfab P/N 5600CI
Double-
Wall
Heatfab Saf-T Vent CI Plus
P/N CCA06Lx **
Heatfab P/N
9614TERM
Heatfab P/N
CCA06RC
H250FD UHXPOSHZ12501 10,100 ft 6 inch Included in UHX kit
NAT &
LP
Single-
Wall
Heatfab Saf-T Vent EZ Seal
P/N 960x *
Heatfab P/N
5690CI ‡”
Heatfab P/N 5600CI
Double-
Wall
Heatfab Saf-T Vent CI Plus
P/N CCA06Lx **
Heatfab P/N
CCE06WP ‡
Heatfab P/N
CCA06RC
H250FDN UHXPOSHZ12502 2,000 ft 4 inch
Heatfab P/N 1501329001
or
DuraVent P/N 810003683
NAT
ONLY
Single-
Wall
Heatfab Saf-T Vent EZ Seal
P/N 940x *
or
DuraVent FasNSeal P/N
FSVLx04 †
Heatfab P/N
9414TERM
or
DuraVent P/N
FSTT4
Heatfab P/N
5400CI or
DuraVent P/N
FSRC4
Double-
Wall
Heatfab Saf-T Vent CI Plus
P/N CCA04Lx **
or
DuraVent FasNSeal W2
P/N W2-x04 †
Heatfab P/N
9414TERM
or
DuraVent P/N
FSTT4
Heatfab P/N
CCA04RC
or
DuraVent P/N
W2-RC4
H300FD
H350FD
H400FD
UHXPOSHZ13001
UHXPOSHZ13501
UHXPOSHZ14001
10,100 ft 8 inch Included in UHX kit
NAT &
LP
Single-
Wall
Heatfab Saf-T Vent EZ Seal
P/N 980x *
Heatfab P/N
5890CI ‡
Heatfab P/N 5800CI
Double-
Wall
Heatfab Saf-T Vent CI Plus
P/N CCA08Lx **
Heatfab P/N
CCE08WP ‡
Heatfab P/N
CCA08RC
H400FD
H500FD
UHXPOSHZ14002
UHXPOSHZ15002
2,000 ft 6 inch
Heatfab P/N 1501646501
or
DuraVent P/N 810003725
NAT &
LP
Single-
Wall
Heatfab Saf-T Vent EZ Seal
P/N 960x *
or
DuraVent FasNSeal P/N
FSVLx06 †”
Heatfab P/N
9614TERM
or
DuraVent P/N
FSTT6
Heatfab P/N
5600CI or
DuraVent P/N
FSRC6
Double-
Wall
Heatfab Saf-T Vent CI Plus
P/N CCA06Lx **
or
DuraVent FasNSeal W2
P/N W2-x06 †
Heatfab P/N
9614TERM
or
DuraVent P/N
FSTT6
Heatfab P/N
CCA06RC
or
DuraVent P/N
W2-RC6
* For Heatfab single-wall vent pipe section length, “x” should be: 1, 2, 4, 5, or 7, where 1=6 inches, 2=12 inches, 4=18 inches, 5=24 inches, and 7=36 inches.
** For Heatfab double-wall vent pipe section length, “x” should be: 06, 09, 12, 18, 24, or 36, indicating the length of the vent pipe section in inches.
† For DuraVent vent pipe section length, “x” should be: 6, 12, 18, 24, or 36, indicating the length of the vent pipe section in inches.
‡ For these horizontal terminals, the wall penetration is included from the vent manufacturer. On all others, it must be ordered separately.