Installation Guide

Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
35
TEMPERATURE ADJUSTMENT:
This pool heater is equipped with a digital thermostat which allows the user to select the desired water
temperature. The heater will then function automatically to maintain the desired temperature. The heater has
3 modes of operation:
1. STANDBY: in this mode, the heater will not function to heat the water.
2. SPA: in this mode, the heater will automatically function to maintain the water temperature setting for
SPA mode.
3. POOL: in this mode, the heater will automatically function to maintain the water temperature setting
for POOL mode.
Use the MODE button to change modes. The indicator lights will illuminate to show which mode the
heater is currently in. Each mode has its own temperature setting, allowing the user to have 2 individual
pre-set temperature settings. To adjust the temperature while in SPA or POOL mode, use the UP and DOWN
buttons. The numeric display will ash to indicate the temperature setting is being displayed / adjusted. When
the numeric display is not ashing, the actual water temperature is being displayed. The temperature settings
for both SPA and POOL modes are initially set at the factory to 65°F. The minimum allowed settings for SPA
and POOL modes are both 65°F. The maximum allowed settings for SPA and POOL modes are adjustable up
to 104°F using the temperature lockout feature (see below).
After selecting SPA or POOL mode or adjusting the temperature setting, it is normal for the heater to
delay up to 10 seconds before the heater starts operating. This delay is an internal self-test of the heater. On
occasion, the numeric display may show a diagnostic error code; refer to list of diagnostic error codes in Fig-
ure 31. Pressing the MODE button to cycle to STANDBY and back to SPA or POOL will clear a diagnostic
error code. When clearing a diagnostic error code this way, it is normal for the heater to delay up to 5 seconds
before resuming normal operation, assuming the diagnostic error code does not re-appear.
diagnostic error code this way, it is normal for the heater to delay up to 5 seconds before
resuming normal operation, assuming the diagnostic error code does not re-appear.
Figure 27: User interface keypad
TEMPERATURE LOCK-OUT
The digital thermostat in this pool heater allows the user to lock the maximum temperature
setting allowed. This feature is useful for preventing unauthorized users from manually adjusting
the temperature settings higher than desired. On a new heater, the maximum allowed
temperature lock settings are initially set at the factory to 90°F for POOL mode, and 104°F for
SPA mode. To adjust these settings, use the following procedure:
1. Use the MODE button to put the heater in STANDBY mode.
2. Press and hold both the UP and DOWN buttons at the same time.
3. After 3 seconds, the thermostat enters maximum temperature lock adjustment mode.
4. The SPA indicator light illuminates and the numeric display shows the current SPA mode
maximum temperature lock setting. Both the SPA indicator light and the numeric display
flashes rapidly when in adjustment mode.
5. Use the UP and DOWN buttons to set the desired maximum temperature lock setting.
When finished, press the MODE button.
6. The POOL indicator light illuminates and the numeric display shows the current POOL
mode maximum temperature lock setting. Both the POOL indicator light and the
numeric display flashes rapidly when in adjustment mode.
7. Use the UP and DOWN buttons to set the desired maximum temperature lock. When
finished, press the MODE button.
8. The heater will return to STANDBY mode.
Numeric Display
Buttons
Indicator Lights