Specification

ESR-1078
|
Most Widely Accepted and Trusted Page 8 of 8
TABLE 5—CONNECTION GEOMETRY REQUIREMENTS
1
CONDITION
MINIMUM DISTANCE OR SPACING (inches)
TimberLOK, OlyLog
and HeadLOK
LedgerLOK,
LogHog, TrussLOK
and TrussLOK-Z
ThruLOK
End distance
Loading toward end
3
3
3
/
4
3
3
/
8
Loading away from end
2
2
3
/
8
2
3
/
8
Loading perpendicular to grain
2
2
3
/
8
2
3
/
8
Edge distance
Any load direction
1
3
/
4
1
3
/
4
2
Spacing between fasteners in a row
Loading parallel to grain
2
7
/
8
3
1
/
2
3
1
/
2
Loading perpendicular to grain
2
2
3
/
8
2
3
/
8
Spacing between rows
In-line rows
1
1
1
/
4
1
1
/
4
Staggered rows
2
1
/
2
5
/
8
5
/
8
For SI: 1 inch = 25.4 mm.
1
End distances, edge distances and screw spacing must be sufficient to prevent splitting of the wood, or as required by this table, whichever is more
restrictive.
2
Values for spacing between staggered rows apply where screws in adjacent rows are offset by half of the spacing between screws in a row.
TABLE 6—RECOGNIZED EXPOSURE CONDITIONS FOR COATED FASTENMASTER LOK SERIES FASTENERS
1
EXPOSURE
CONDITION
TYPICAL APPLICATIONS
RECOGNITION LIMITATIONS
1
Treated wood in dry use applications
Limited to use where equilibrium moisture content of the chemically treated
wood meets the dry service conditions as described in the NDS.
3
General construction
Limited to freshwater and chemically treated wood exposure, e.g., no
saltwater exposure.
1
Recognized exposure conditions apply only to FastenMaster LOK Series fasteners having the recognized proprietary corrosion-resistant coating with a
lubricious clear top coat.
TABLE 7—PRODUCT NAME CORRELATION
OMG PRODUCT NAME
CORRESPONDING NAME FOR MITEK INDUSTRIES
TimberLOK/OlyLog
-
HeadLOK
-
LedgerLOK
-
LogHog
-
TrussLOK
TrussLOK-EWP
TrussLOK-Z
TrussLOK-Girder
ThruLOK
-