HORIZONTAL VENTING
Kit No. H Max. Run
DVP-TRAP 24" (610 mm)
Figure 11. Corner Installation
NOTE: This model is tested and approved to
use 45° elbows in corner installations. Howev-
er, 90° elbows will result in better performance.
The use of two 90
0
elbows in a corner installation
will affect space requirements (see Figure 2).
3. Match the amount of vertical you have in the sys-
tem with the chart to find the appropriate position
to set the Flue Restrictor (see Figure 9).
1 2 3 4 5
SETTINGS
1 2 3 4 5
Figure 10
4. Center the Flue Restrictor on vent and secure in
place by using two self-tapping screws (see Fig-
ure 10).
5. Reinstall the Exhaust Shield.
- CHART -
Vertical
Top Vent
NG
Top Vent
LP
Rear Vent
NG
Rear Vent
LP
4' 1-1
No
Restrictor
No
Restrictor
No
Restrictor
8' 2-2 1-2 1-1
No
Restrictor
15' 3-3 3-2 2-2 1-2
20' 3-4 3-3 3-3 2-3
25' 3-4 3-3 3-3 2-3
30' 4-4 3-4 3-4 3-3
35' 4-4 3-4 3-4 3-3
40' 5-4 4-4 4-4 3-4
Figure 9.