Figure 5.2 Recommended Chimney Locations
E. Locating Fireplace & Chimney
Location of the replace and chimney will affect perfor-
mance.
Install through the warm airspace enclosed by the
building envelope. This helps to produce more draft,
especially during lighting and die-down of the re.
Penetrate the highest part of the roof. This minimizes
the effects of wind loading.
Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
Minimize the use of chimney offsets.
Consider the replace location relative to oor and ceiling
and attic joists.
Take into consideration the termination requirements in
Section 8 and Section 9.
NOTICE: Locating the replace in a basement or in a location
of considerable air movement can cause intermittent smoke
spillage from replace. Do not locate replace near
frequently open doors
central heat outlets or returns