User Manual

Page | 10
-
Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the grill
is manufactured for.
This natural gas grill is designed to operate on natural gas ONLY, at a pressure regulated at 4 water
column (W.C.) when equipped with the correct natural gas orifices on the valves and a natural gas
regulator on the supply line regulated at the residential meter.
NOTE: Supply line must be ½” ID from gas supply to regulator.
We recommend consulting a local licensed plumber to insure proper gas volume.
IMPORTANT: Never connect the grill to an unregulated gas supply.
Natural gas connections must be performed by a licensed contractor or local gas company
representative.
NG Regulator
IMPORTANT: NEVER use grill without leak testing this connection.
Natural gas regulator model: GR120N
Gas pressure: 4
Maximum rate working pressure: 1/2 PSIG
Natural Gas Supply Connection and Disconnection
1. Make sure all burner valves are in the “OFF” position.
2. To connect-push back sleeve of socket, insert plug release sleeve. Push plug until sleeve snaps
forward locking plug into socket. (THIS AUTOMATICALLY TURNS ON GAS.)
3. To disconnect: Push sleeve back and pull out plug. (THIS AUTOMATICALLY SHUTS OFF GAS.)
4. Connected hose assembly shall be of adequate length and capacity for intended application. Final
assembly must be tested for leaks.
Natural Gas Hook-up