Use and Care Manual
-6-
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
-7-
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
1. The Fan will operate automacally when the heater is powered up to an electrical outlet.
2. Allow the heater fan to run for 20 seconds to purge fuel (the first me you use the heater this step is unnecessary).
3. Slowly open the main gas valve at the propane cylinder.
4. Depress and rotate the valve control knob to the “
” posion to ignite the fuel.
5. Aer the heater lights, keep the knob depressed for 30 seconds or unl the thermocouple warms suciently to maintain
combuson.
6. If the heater does not remain lit, repeat the lighng instrucons.
7. Turn the knob to the desired heat seng.
1. Tightly close the gas valve at the propane cylinder.
2. Allow the heater to purge any remaining gas from the hose.
3. Turn the control knob to the “O” posion.
4. Disconnect the power cord from the power source.
5. Disconnect the hose assembly from the cylinder and store the cylinder outdoors.
6. Allow the heater to cool before moving or adjusng the heater.
1. Securely close the gas valve at the propane cylinder.
2. Disconnect the heater from its power source.
3. Restart following “Start” procedure.
1. Inspect the heater before and aer each use, and at least annually by a qualified
service technician.
2. Inspect the hose assembly for abrasions or wear, or for cuts. If damaged, replace the
hose prior to operang the heater. Before each use, check the so “O” ring seal of
the POL fing. If the “O” ring is cut,scuffed, or otherwise damaged, replace it before
using the heater.
3. Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.
4. Store the propane cylinder in accordance with the Standard for the Storage and Handling of Liquefied Petroleum Gases,
NFPA 58 and Natural Gas and Propane Installaon Code, CSA B149.1.tore the cylinder outdoors and in accordance with
Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B 149.1, Natural
Gas and Propane Installaon Code.
At least annually, have the heater inspected and serviced by a qualified service technician. NEVER use a heater that has been
modified from its original condion. For original manufacturer’s parts, contact PowerFast Products Group at (423) 837-5155.
“O” Ring