OPTIONAL WIRING
Thisxtureisprovidedwithasensorratedfor500Watts.Sincethexturewattageisless
than500watts,thenadditionallightingloadcanbecontrolled.Forexample,ifthextureis
ratedfor100watts,then400wattsofadditionallightingloadcanbecontrolled.
Whendeterminingwhataxtureisratedfor,donotsimplylookattheratingonthelampin
thexture.Lookatthemarkingwhichspeciesthemaximumlampwattageforwhichthe
xtureissuitable.
Onceyouhaveselectedthexturestobeconnectedanddeterminedtheirmaximumratings,
addtheseratingsup.Forinstance,ifyouhave3xturesrated100Watts,150Watts,and
75Wattsrespectively,youhaveatotalloadof325Watts.
Wiring Diagram 1 –Whenwiringtocontrolastandardlightxture:Stripthemotionsensor’s
redwireandconnecttothestandardlight’sblackwire.Connectallwhitewirestogether.
Totalxtureratingsmustnotexceed500Watts(4.1A).
Wiring Diagram 2 –Whenwiringtocontrolanothermotionsensinglightxture(Master/
Slave):Striptheredwireinbothlightxtures.Connecttheredwireofthecontrolling(master)
xturetotheredandblackwiresofthecontrolled(slave)xture.Connectallwhitewires
together.Totalxtureratingsmustnotexceed500Watts(4.1A).
Wiring Diagram 1
Black
White
Green
or Bare
Light
Fixture
Light
Fixture
Wiring Diagram 2
(Standard)
Master Slave
Itisalsopossibletowiretwomotionlightssothateitherxturewillturnonbothlightsatthe
sametime(dualmastersystem).Itisrecommendedthatonlypeoplewithplentyofelectrical
experienceattemptthisconguration.Pleasecallourcustomerservicenumber(1-800-858-
8501-Englishspeakingonly)beforeattemptingthiswiring.If the dual master wiring is not
done correctly, it can destroy both motion sensing fixtures and void your warranty.