3. Loosentheclampscrewinthe
sensor ball joint and gently
rotatethesensor.
4. Walk through the coverage
area noting where you are
whenthelightsturnon(also,
theLEDwillashseveraltimes
whenmotionisdetected).Move
thesensorheadup,down,or
sidewaystochangethecover-
agearea.Keep the sensor at
least 1" (25 mm) away from
the bulbs.
5. AdjusttheRANGEasneeded.
RANGE set too high may
increasefalsetriggering.
6. Secure the sensor head by
tightening the clamp screw.
Donotovertightenthescrew.
7. SettheamountofTIMEyouwantthelightstostay
onaftermotionisdetected(1,5,or20minutes).
8. SettheDualBrite
®
switchtotheamountoftimeafter
duskyouwantthelightsonatlowlevel(Off,3,6
Hrs.,Dusk-to-Dawn).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
Bottom of Sensor
Avoid aiming the sensor at:
•Objects that change temperature rapidly, such as
heating vents and air conditioners.These heat
sourcescouldcausefalsetriggering.
•Areaswherepets or trafficmaytriggerthecontrol.
•Nearby large, light-colored objectsreectinglight
maytriggertheshut-offfeature.Donotpointother
lightsatthesensor.
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST 1 5 20
MINUTES
OFF
3
6
DUSK TO
DAWNHOUR
C
R
E
E
P
Z
O
N
E
B
O
O
S
T
Maximum
Maximum Range Coverage Angle
Motion
Motion
15ft.
(4.6m)
70ft. 100ft.
(21m) (30.5m)
Boosted
Sensor
240°
Least Sensitive Most Sensitive
NOTE:
Ifxtureismountedhigherthan8ft.(2.4m),aiming
thesensordownwillreducecoveragedistance.
Thedetectorislesssensitivetomotiondirectlytowardsit.
CreepZone™
CreepZone™
CreepZone™
CreepZone™
NOTE: Creep Zone™ is a new zone of detection
whichwasaddedasanoptiontoselectHeath
®
/Zenith
motionsensingproducts.Thisfeatureaddsazone
ofdetectionunderthemotionsensor.CreepZone™
requires no additional adjustment and operates in
conjunctionwiththeforward-lookingsensor.
TEST AND ADJUSTMENT
1. Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
1
/
2
minute warm up period
beforeitwilldetectmotion.Whenrstturned
on,wait1
1
/
2
minutes.
2. Turnthe RANGE control to the medium position
(halfway between MIN and MAX), DualBrite
®
to
OFF,andtheON-TIMEcontroltotheTESTposition.