Operation Manual

124 Machine mode of operation
3.10 Load monitoring (option)
Adapting the limit values
After successful reference machining, the control uses the reference
values and the predefined factors specified in the machine parameters
to calculate the limit values.
You can adapt the calculated limit values as required for the
subsequent production.
To display limit values, select the menu View > Edit load data—the
control opens the "Set load data" form
Check the limit values
If required, adapt the parameters PG1, PG2 or WGF
ADAPT LIMIT VALUES
Be sure to adapt the correct limit values. First, press the
Next zone and Next axis soft keys to select the form
containing the limit values you want to change! As an
alternative, you can use the selection lists of the ZO and
AX parameters to select the correct form. Save the
changes separately for each axis by pressing the Save soft
key!
Reference machining does not have to be repeated after
adapting the limit values. You can continue production
with the adapted limit values.