Corp. Refrigerator User Manual

Model CMC/CMR-103,104,105,106,107
303 2-3
2-5. REFRIGERANT Design Pressure
INFORMATION High Low
CMC-103 R22 1.5 lbs (0.680 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
CMC-104 R22 1.5 lbs (0.680 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
UL Specs CMC-105 R22 2.5 lbs (1.134 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
CMC-106 R22 2.5 lbs (1.134 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
CMC-107 R22 2.5 lbs (1.134 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
CMC-103 R134A 1.65 lbs (0.750 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
CMC-104 R134A 1.87 lbs (0.850 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
CE Specs CMC-105 R134A 2.65 lbs (1.200 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
CMC-106 R134A 3.09 lbs (1.400 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
CMC-107 R134A 3.53 lbs (1.600 kg) 440psig 162 psig
(30.3 bar) (11.2 bar)
2-6. DRAIN CONNECTION The cold tops-remote (CMRs), requires 1-1/2 inch (38.1 mm)
drain connection. CMCs do not require a plumbed drain.
Refrigerant Type Amount of Refrig.
2-4. LOCATION Place the cold tops in an area where product can be loaded and
unloaded without interruption. For proper operation, level the unit
by adjusting the bolts under the base, and leave 3 feet (91.44 cm)
clearance behind the unit for ventilation and service.
For maximum efficiency, units should be operated in an air-condi-
tioned environment, with maximum air temperature of 75° F
(24° C), and 55% relative humidity.
Wait at least 4 hours before plugging the unit into an
electrical supply. The gases and oils in the refrigeration
system needs to settle before operating the compressor, or
damage to the compressor could result.