MSDS

M A T E R I A L S A F E T Y D A T A S H E E T
Page 3 of 6
HE287SF - 287 SOLAR-FLEX WHITE ROOF COATING
8. Exposure Controls/Personal Protection
Engineering Controls
Use with adequate general and local exhaust ventilation. When used outdoors, stay well away from building air intakes
or close and seal the intakes to prevent product from entering building.
Eye/Face Protection
Safety glasses with side shields or goggles recommended.
Skin Protection
Use with chemical-protective gloves to prevent skin contact.
Respiratory Protection
This product is an encapsulated mixture which reduces the likelihood of exposure to hazardous particulates. Airborne
exposures to hazardous dusts or mists may be generated by spraying, sanding or grinding.
The level of respiratory protection needed should be based on the evaluation of chemical exposures by a health or
safety professional. If required, use a NIOSH-approved air purifying respirator with organic vapor cartridge and
particulate filter or supplied air respirator. Respirator use may be required due to secondary operations such as mixing,
spraying, sanding, buffing, etc.
Occupational Exposure Limits for individual ingredients (if available) are listed below.
Ingredient(s) - Exposure Limits
calcium carbonate
OSHA PEL-TWA 15 mg/m3 (total dust)
OSHA PEL-TWA 5 mg/m3 (respirable dust)
silica, quartz
ACGIH TLV-TWA 0.025 mg/m3
OSHA PEL-TWA 30mg/m3 / (%SiO2+2) (total dust)
OSHA PEL-TWA 10 mg/m3/ (%SiO2+2) (respirable dust)
titanium dioxide
ACGIH TLV-TWA 10 mg/m3 (respirable)
OSHA PEL-TWA 15 mg/m3 (total dust)
9. Physical And Chemical Properties
Appearance
Creamy, white liquid
Odor
Paint-like odor
Chemical Type: Mixture
Physical State: Liquid
Melting Point: 32 °F 0 °C
Boiling Point: 212 °F
Specific Gravity: 1.44
Vapor Pressure: 760@ 212ºF
Vapor Density: >1
pH Factor: 8.0-9.0
Solubility: dispersible
Evaporation Rate: <1