User Manual

EN
©2016 Hestan Commercial Corporation
18
LP TANK RESTRAINT
If you purchased a Hestan Grill with Side Burner on a cart, be sure to restrain the LP cylinder by
securing it with the retention bolt on the slide-out tray as shown below. It is important the tank
does not fall over or stretch the hose which could cause a gas leak.
LEAK TESTING
GENERAL
Although all gas connections on your Hestan side burner are leak tested at the factory prior
to shipment, a complete gas tightness check must be performed at the installation site due to
possible movement in shipment, or excessive pressure unknowingly being applied to parts of the
unit. Periodically check the whole system for leaks, or immediately check if the smell of gas is
detected.
BEFORE TESTING
Do not smoke while leak testing.
Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water for leak testing
purposes.
Apply the solution to the gas fittings by using a spray bottle or a brush.
For LP units, always check with a full LP cylinder.
GAS CONNECTIONS
(continued)