User Manual

DS-73xxHUI-K4, DS-73xxHQI-K4, DS-90xxHUI-K8 DVR User Manual
UM DS-73xxHUI-K4 DS-73xxHQI-K4 DS-90xxHUI-K8 092017NA 217
2) If the HDD status is “Uninitialized,” check the corresponding HDD checkbox and click the
“Init button.
Step 3 Verify the HDD is detected and is in good condition.
1) Select “Menu > System Configuration > HDD > General.
2) If the HDD is not detected or the status is “Abnormal,” replace the dedicated HDD
according to the requirement.
Step 4 Check if the fault is solved by step 1 to step 3.
1
) If it is solved, finish the process.
2) If not, contact an engineer from our company for further analysis.
Live view becomes stuck when video outputs locally.
Possible Reasons:
The frame rate has not reached the real-time frame rate.
Step 1 Check the parameters of Main Stream (Continuous) and Main Stream (Event).
Step 2 Select “Menu > Record > Parameters > Record,and set the resolution of Main Stream
(Event) the same as the one of Main Stream (Continuous).
Step 3 Verify the frame rate is real-time frame rate.
Step 4 Select “Menu > Record > Parameters > Record,and se
t the Frame Rate to Full Frame.
Step 5 Check if the fault is solved by the above steps.
Step 6 If it is solved, finish the process.
Step 7 If not, contact an engineer from our company for further analysis.
When using the device to get live view audio, there is no sound, there is too much noise, or the
volume is too low.
Possible Reasons:
Cable between the pickup and camera is not connected well; impedance mismatches or is
incompatible.
The stream type is not set to “Video & Audio.
Step 1 Verify the cable between the pickup and camera is connected well, the impedance matches,
and is compatible.
Step 2 Verify the setting parameters are correct.
Step 3 Select “Menu > Record > Parameters > Record,and se
t the Stream Type to “Audio & Video.
Step 4 Check if the fault is solved by the above steps.