User Manual
Table Of Contents
- Chapter 1 Introduction
- Chapter 2 Getting Started
- 2.1 Device Startup and Activation
- 2.2 Using Wizard for Basic Configuration
- 2.3 Adding and Connecting the IP Cameras
- Chapter 3 Live View
- Chapter 4 PTZ Controls
- Chapter 5 Recording and Capture Settings
- 5.1 Configuring Parameters
- 5.2 Configuring Recording and Capture Schedule
- 5.3 Configuring Motion Detection Recording and Capture
- 5.4 Configuring Alarm Triggered Recording and Capture
- 5.5 Configuring VCA Event Recording
- 5.6 Manual Recording and Continuous Capture
- 5.7 Configuring Holiday Recording and Capture
- 5.8 Configuring Redundant Recording and Capture
- 5.9 Configuring HDD Group for Recording and Capture
- 5.10 Files Protection
- Chapter 6 Playback
- 6.1 Playing Back Record Files
- 6.2 Auxiliary Functions of Playback
- Chapter 7 Backup
- Chapter 8 Alarm Settings
- Chapter 9 POS Configuration
- Chapter 10 VCA Alarm
- 10.1 Face Detection
- 10.2 Vehicle Detection
- 10.3 Line Crossing Detection
- 10.4 Intrusion Detection
- 10.5 Region Entrance Detection
- 10.6 Region Exiting Detection
- 10.7 Unattended Baggage Detection
- 10.8 Object Removal Detection
- 10.9 Audio Exception Detection
- 10.10 Sudden Scene Change Detection
- 10.11 Defocus Detection
- 10.12 PIR Alarm
- Chapter 11 VCA Search
- Chapter 12 Network Settings
- Chapter 13 RAID
- Chapter 14 HDD Management
- Chapter 15 Camera Settings
- Chapter 16 NVR Management and Maintenance
- Chapter 17 Others
- Chapter 18 Appendix
Network Video Recorder User Manual
151
8.2 Setting Sensor Alarms
Purpose:
Set the handling action of an external sensor alarm.
Step 1 Enter Alarm Settings of System Configuration and select an alarm input.
Menu> Configuration> Alarm
Select Alarm Input tab to enter Alarm Input Settings interface.
Figure 8-4 Alarm Status Interface of System Configuration
Step 2 Set up the handling action of the selected alarm input.
Check the Enable checkbox and click Settings button to set up its alarm response actions.
Figure 8-5 Alarm Input Setup Interface
Step 3 (Optional) Enable the one-key disarming for local alarm input 1 (Local<-1).
1) Check the checkbox of Enable One-Key Disarming.
2) Click the Settings button to enter the linkage action settings interface.
3) Select the alarm linkage action (s) you want to disarm for the local alarm input1. The selected linkage
actions include the Full Screen Monitoring, Audible Warning, Notify Surveillance Center, Send Email
and Trigger Alarm Output.