Use and Care Manual

English 7
LED Meaning
No filter
Fit the filter bag fitted correctly.
4 Technical data
4.1 Technical data
Note
For details of the rated voltage, current, frequency and/or input power, please refer to the power tool’s
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer’s power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
DD-WMS 100
Protection class
I
Protection class
IPX4
Weight in accordance with EPTA procedure 01/2003
43.4 lb
(19.7 kg)
Operating temperature
37 …104
(3 …40 ℃)
Recommended temperature range for transport and stor-
age (without water in the container)
−13 …158
(−25 …70 ℃)
Suction hose length
16 ft
(5 m)
Pressure hose length
16 ft - 9 in
(5.1 m)
Supply cord length
15 ft - 9 in
(4.8 m)
Container capacity
32
Water capacity
14
Volumetric flow rate (air)
74 ℓ/s
Water flow rate
3 ℓ/min
Water pressure
7 bar
Printed: 19.07.2017 | Doc-Nr: PUB / 5306586 / 000 / 03