SCO 6-A22 English Printed: 12.12.
1 Information about the documentation 1.1 About this documentation • • • Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and use of the product. Observe the safety instructions and warnings in this documentation and on the product. Always keep the operating instructions with the product and make sure that the operating instructions are with the product when it is given to other persons. 1.2 Explanation of signs used 1.2.
1.4 Product information Hilti products are designed for professional use and may be operated, serviced and maintained only by trained, authorized personnel. This personnel must be informed of any particular hazards that may be encountered. The product and its ancillary equipment can present hazards if used incorrectly by untrained personnel or if used not in accordance with the intended use. The type designation and serial number are stated on the rating plate.
▶ ▶ ▶ ▶ ▶ Prevent unintentional starting. Ensure the switch is in the off‐position before connecting to battery pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents. Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury. Do not overreach. Keep proper footing and balance at all times.
▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ ▶ Never touch the clamping nut or collet when the accessory tool gets stuck and stalls. Take breaks between working and do physical exercises to improve the blood circulation in your fingers. Exposure to vibration during long periods of work can lead to disorders of the blood vessels and nervous system in the fingers, hands and wrists. The power tool is not intended for use by debilitated persons who have received no special training.
3 Description 3.1 Overview of the product English Printed: 12.12.
@ ; = % & ( ) + Vacuum cleaner hose connector (accessory) LED lights Depth gauge Securing screw On/off switch Switch-on interlock release button Accessory tool Collet § / : ∙ $ £ | Clamping nut Insulated gripping surface Spindle lockbutton Insulated gripping surface Air vents Release button with additional function (charge state display activation) Battery 3.2 Intended use The product described is a hand-held cordless cut-out tool.
Collet diameter Cutting bit shank diameter Battery operating temperature Battery charging starting temperature Battery storage temperature SCO 6-A22 1/8", 5/32", 1/4" 1/8", 5/32", 1/4" 1 ℉ …140 ℉ (−17 ℃ …60 ℃) 14 ℉ …113 ℉ (−10 ℃ …45 ℃) −4 ℉ …104 ℉ (−20 ℃ …40 ℃) 6 Operation 6.1 Preparations at the workplace CAUTION Risk of injury! Inadvertent starting of the product. ▶ Remove the battery before making any adjustments to the power tool or before changing accessories.
6.1.2 Removing the battery 1. Press the release buttons on the battery. 2. Pull the battery out toward the rear. 6.1.2.1 Fitting an accessory tool Risk of damage. The collet can break if tightened when no accessory tool is fitted. ▶ 1. 2. 3. 4. 5. 6. Never tighten the collet when no accessory tool is fitted. Clean the connection end of the accessory tool. Check that the collet has been fitted. Press the spindle lockbutton and hold it in this position.
6.1.4 Changing the collet 1. 2. 3. 4. Press the spindle lockbutton and hold it in this position. Use a hex. wrench to release and remove the clamping nut. Remove the existing collet and fit the collet you wish to use. Screw on and tighten the clamping nut and then release the spindle lockbutton. 6.1.5 Fitting the depth gauge WARNING Risk of injury! A damaged depth gauge may present a risk of inadvertent contact with the accessory tool. ▶ 1. 2. 3. 4.
6.1.6 Fitting the vacuum cleaner hose connector 1. Remove the accessory tool. → page 10 2. Fit the hose connector to the power tool and bring it into the desired position. 3. Allow the retaining lugs to engage. 6.2 Types of work Warning! Risk of damage! ▶ ▶ Operation of the direction of rotation and/or function selector switch while the tool is running may result in damage to the tool. Do not operate this switch while the tool is running.
1. Push the safety lock forward. ◁ The on/off switch is unlocked. 2. Press the on/off switch as far as it will go. ◁ The power tool’s motor runs at no-load speed. 6.2.3 Switching off ▶ Release the on/off switch. ◁ The safety lock jumps automatically into the locked position. 6.2.4 Operation 1. Hold the power tool securely so that the accessory tool is not in contact with the working surface. 2. Switch on. → page 12 3.
Note To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare parts, consumables and accessories approved by Hilti for use with the product can be found at your local Hilti Center or online at: www.hilti.com 8 Transport and storage of cordless tools Transport CAUTION Inadvertent starting during transport. Uncontrolled starting during transport may occur if the battery is fitted, thereby resulting in damage to the tool.
Trouble or fault The motor has no braking effect. Possible cause The power tool was overloaded briefly. Action to be taken ▶ Release the on/off switch and then press it again. 10 Disposal WARNING Risk of injury. Hazards presented by improper disposal. ▶ ▶ ▶ Improper disposal of the equipment may have the following consequences: The burning of plastic components generates toxic fumes which may present a health hazard.
Printed: 12.12.
Hilti = registered trademark of Hilti Corp., Schaan Printed: 12.12.