S-BT Threaded Fastener Specification
Table Of Contents
- 1.1 Definition
- 1.2 The S-BT system
- 1.3 Fastening mechanism
- 1.4 S-BT system features and benefits – simplified fastening to steel
- 2.1 Grating fastening system
- 2.2 Grating fastening system X-FCS-R
- 2.3 S-BT with MM and MQ installation channel system
- 2.4 Fastening instrumentation, junction boxes and lighting
- 2.5 Fastening cable / conduit connectors
- 2.5 Fastening cable tray supports
- 2.7 Electrical connections
- 3.1 Product data
- 3.2 Load data
- 4.1 Instruction for use - S-BT-MF M6, M8, M10, W6, W10
- 4.2 Instruction for use - S-BT-MF M8/7 AN 6
- 4.3 Instruction for use - S-BT-MR M6, M8, M10, W6, W10 SN 6
- 4.4 Instruction for use - S-BT-MR M8/7 SN 6
- 4.5 Instruction for use - S-BT-MR M6, M8, M10, W6, W10 SN 6 AL
- 4.6 Instruction for use - S-BT-MR M8/7 SN 6 AL
- 4.7 Instruction for use - S-BT-GF M8/7 AN 6
- 4.8 Instruction for use - S-BT-GR M8/7 SN 6
- 4.9 Instruction for use - S-BT-GR M8/7 SN 6 AL
- 4.10 Instruction for use – S-BT-EF M6/W6/M8
- 4.11 Instruction for use – S-BT-EF M10/W10
- 4.12 Instruction for use – S-BT-ER M6/W6/M8
- 4.13 Instruction for use – S-BT-ER M10/W10
- 4.14 Instruction for use – S-BT-EF W10 HC AWG2/0 and S-BT-EF M10 HC 35/120
- 4.15 Instruction for use – S-BT-ER W10 HC AWG2/0 and S-BT-ER M10 HC 35/120
- 5.1 Nomenclature and symbols
- 5.2 Design concepts
- 5.3 Static capacity of the S-BT threaded stud
- 5.4 Vibration effects on S-BT threaded stud fastenings
- 5.5 Resistance of S-BT fastenings under dynamic tensile loading
- 5.6 Effect of S-BT threaded stud fastenings on the fatigue strength of base material structural steel
- 5.7 Influence of glue coatings on the loosening torque
- 5.8 S-BT-ER and S-BT-EF screw-in threaded studs for electrical connections
- 5.9.5 Conductivity disc of S-BT-ER / -EF electrical connectors
- 5.9.4 Stainless steel S-BT studs
- 5.9.3 Carbon steel S-BT studs
- 5.9.2 Galvanic (contact) corrosion
Specifications page 11
S-BT Screw-in threaded studs
X-SEA-R30M8 extensionadaptor
0
X-SEA-R30M8extensionadaptor
ForusewithX-FCM-RandX-FCM-RNGgratingfastenersforfasteningofgrating
withaheightinexcessof50mm[1.97"].
FastenerSelectionX-FCM
Designation L[mm/in.]
Grating height
HG, range
[mm/in.]
Grating height with
X-SEA-R30M8
[mm/in.]
X-FCM-R25/30 23/0.91 25–30/0.98–1.18 55–60/2.16–2.36
X-FCM-R1"–1¼" 27/1.06 29–34/1.14–1.34 59–64/2.32–2.52
X-FCM-R35/40 33/1.30 35–40/1.38–1.57 65–70/2.56–2.75
X-FCM-R45/50 43/1.69 45–50/1.77–1.97 75–80/2.91–3.15
X-FCM-M25/30 23/0.91 25–30/0.98–1.18
X-FCM-M1”–1¼” 27/1.06 29–34/1.14–1.34
X-FCM-M35/40 33/1.30 35–40/1.38–1.57
X-FCM-M45/50 43/1.69 45–50/1.77–1.97
X-FCM-M31/36L
*)
25/0.98 31–36/1.22–1.42
*)
GratingheightHG31mmand32mm:UsewithS-BT-GFM8/7orS-BT-GRM8/7
GratingheightHG33mmto36mm:UsewithS-BT-MFM8/15orS-BT-MRM8/15
Installation instructions X-FCM
1
3.1
!
!
3.0
5
T
rec
2
≥18
≥18
4
Lay grating section in
nalposition.
Pre-drilluntilshoulder
grinds a shiny ring.
The drilled hole and the
areaarounddrilledhole
mustbecleanandfree
fromliquidsanddebris.
Expandgratingopenings
if necessary.
Screw-inS-BTstudsinto
drilled hole.
Pre-drillwithTS-BT
stepped drill bit.
TightenX-FCMdiscs
with5mmAllen-type
bitwiththesuited
installationtorque.