S-BT Threaded Fastener Specification
Table Of Contents
- 1.1 Definition
- 1.2 The S-BT system
- 1.3 Fastening mechanism
- 1.4 S-BT system features and benefits – simplified fastening to steel
- 2.1 Grating fastening system
- 2.2 Grating fastening system X-FCS-R
- 2.3 S-BT with MM and MQ installation channel system
- 2.4 Fastening instrumentation, junction boxes and lighting
- 2.5 Fastening cable / conduit connectors
- 2.5 Fastening cable tray supports
- 2.7 Electrical connections
- 3.1 Product data
- 3.2 Load data
- 4.1 Instruction for use - S-BT-MF M6, M8, M10, W6, W10
- 4.2 Instruction for use - S-BT-MF M8/7 AN 6
- 4.3 Instruction for use - S-BT-MR M6, M8, M10, W6, W10 SN 6
- 4.4 Instruction for use - S-BT-MR M8/7 SN 6
- 4.5 Instruction for use - S-BT-MR M6, M8, M10, W6, W10 SN 6 AL
- 4.6 Instruction for use - S-BT-MR M8/7 SN 6 AL
- 4.7 Instruction for use - S-BT-GF M8/7 AN 6
- 4.8 Instruction for use - S-BT-GR M8/7 SN 6
- 4.9 Instruction for use - S-BT-GR M8/7 SN 6 AL
- 4.10 Instruction for use – S-BT-EF M6/W6/M8
- 4.11 Instruction for use – S-BT-EF M10/W10
- 4.12 Instruction for use – S-BT-ER M6/W6/M8
- 4.13 Instruction for use – S-BT-ER M10/W10
- 4.14 Instruction for use – S-BT-EF W10 HC AWG2/0 and S-BT-EF M10 HC 35/120
- 4.15 Instruction for use – S-BT-ER W10 HC AWG2/0 and S-BT-ER M10 HC 35/120
- 5.1 Nomenclature and symbols
- 5.2 Design concepts
- 5.3 Static capacity of the S-BT threaded stud
- 5.4 Vibration effects on S-BT threaded stud fastenings
- 5.5 Resistance of S-BT fastenings under dynamic tensile loading
- 5.6 Effect of S-BT threaded stud fastenings on the fatigue strength of base material structural steel
- 5.7 Influence of glue coatings on the loosening torque
- 5.8 S-BT-ER and S-BT-EF screw-in threaded studs for electrical connections
- 5.9.5 Conductivity disc of S-BT-ER / -EF electrical connectors
- 5.9.4 Stainless steel S-BT studs
- 5.9.3 Carbon steel S-BT studs
- 5.9.2 Galvanic (contact) corrosion
Specifications page 3
S-BT Screw-in threaded studs
3.2.5 RecommendedloadsS-BTwithHilticouplerRC-MFandRC-MR 30
3.2.6 DesignloadsS-BTwithHilticouplerRC-MFandRC-MR 30
3.2.7 Recommendedinteractionformulaforcombinedloading–steelandaluminumbasematerials 31
3.2.8 Basematerialthicknesst
II
and type of bore hole 31
3.2.9 Thicknessoffastenedmaterialt
I
32
3.2.10 Spacing and edge distances 33
3.2.11 Installationtemperatureandservicetemperature 33
3.2.12 Applicationlimitandthicknessofbasematerial 34
3.2.13 Fasteningqualityassuranceandfasteninginspection 34
3.2.14 Fastenerselectionandsystemrecommendation 35
3.2.15 Installationdetails:FasteningS-BTthreadedstudswithstandoffadaptertosteelwithapassivereprotection
(PFP)coating 36
3.2.16 Installation details 37
4. Method Statement
4.1 Instructionforuse–S-BT-MFM6,M8,M10,W6,W10 39
4.2 Instructionforuse–S-BT-MFM8/7AN6 40
4.3 Instructionforuse–S-BT-MRM6,M8,M10,W6,W10SN6 41
4.4 Instructionforuse–S-BT-MRM8/7SN6 43
4.5 Instructionforuse–S-BT-MRM6,M8,M10,W6,W10SN6AL 45
4.6 Instructionforuse–S-BT-MRM8/7SN6AL 46
4.7 Instructionforuse–S-BT-GFM8/7AN6 47
4.8 Instructionforuse–S-BT-GRM8/7SN6 48
4.9 Instructionforuse–S-BT-GRM8/7SN6AL 50
4.10 Instructionforuse–S-BT-EFM6/W6/M8 51
4.11 Instructionforuse–S-BT-EFM10/W10 52
4.12 Instructionforuse–S-BT-ERM6/W6/M8 53
4.13 Instructionforuse–S-BT-ERM10/W10 55
4.14 Instructionforuse–S-BT-EFW10HC4/0andS-BT-EFM10HC120 57
4.15 Instructionforuse–S-BT-ERW10HC4/0andS-BT-ERM10HC120 58
4.16 Instructionforuse–StandoffadapterMFandMR25/50/75/100onsteelwithapassivereprotection(PFP)coating 59
4.16.1 Instructionforuse–CalibrationofdepthgaugeS-DGBTforinstallationofS-BTonPFP-coatedsteel
(e.g.S-BTGRM8/7SN6) 59
4.16.2 Instructionforuse–FasteningofstandoffadapterwithS-BTonPFP-coatedsteel 60
4.17 Instructionsforuse–Attachmentstostandoffadapter(e. g.M8) 61
5. Performance
5.1 Nomenclatureandsymbols 62
5.2 Designconcepts 63
Content Page