S-BT Screw-in threaded studs
1.2.4 Installation tool
Designation Item Description Application
SBT 4-A22 UCD tool Drilling / Setting
SF 4-A22 UCD tool Setting
SFC 22-A
(B22/2.6or5.2Ah)
UCD tool Setting
SFC18-A
(B18/2.6or5.2Ah)
UCD tool Setting
Fortheinstallationprocess,arecommendedtorqueupto13Nmisneeded.The
cordlessdrilldriversSBT4-A22,SF4-A22,SFC22-AandS-FC18-Afulllthe
requirementsfortheinstallationprocess.
1.2.5 S-DG depth gauge with a S-CC calibration card
Designation Item Description Application
S-DGBTM8/7Short6 DepthgaugeforS-BTM8/7_N6 Setting
S-DGBTM8/15Long6 DepthgaugeforS-BTM8/15_N6 Setting
S-DGBTM10-W10/15
Long 6
DepthgaugeforS-BTM10/W10_N6 Setting
S-DGBTM10-W10HC6 DepthgaugeforS-BTM10/W10HC_ Setting
S-CC BT 6
Calibration card for calibration of the
depthgauge(short/longstuds)
Calibration
S-CC BT HC 6
Calibration card for calibration of the
depthgaugeforS-BTM10/W10HC_
Calibration
S-CGBT/7Short6
Checkgaugeforvericationofthe
stand-offforshortstuds(7mm)
Verication
S-CGBT/15Long6
Checkgaugeforvericationofthe
stand-offforlongstuds(15mm)
Verication
S-CGBTHC
Checkgaugeforvericationofthe
stand-offforS-BTM10/W10HC_
Verication
Inordertoensuretheexactscrew-indepthandapropercompressedsealing
washer,theS-BTstudshavetobeinstalledwiththeappropriatedepthgauge.
Withthistoolthescrew-indepthcanbeadjustedinarangeof0–1.5mm(3steps,
0.5mmperstep).
TheS-CCBTcalibrationcardisneededtochecktheinitialstandoffoftheS-BT
stud(ensuretheproperscrew-indepth)andtoadjust/calibratetheS-DGdepth
gauge.AfterndingtherightadjustmentlevelfortheS-DGdepthgauge,thegauge
canbeadjustedandthestudscanbeinstalledwithoutadditionalcheckofthe
S-DGdepthgauge.
Thedepthgaugehastobere-adjusted(calibrated)atfollowingtimes:
• Start of the installation process
•Changeoftheworkingposition(upwards,downwards,horizontal)
andbasematerial(thickness,strength,type)
• Installer change
•Aftereachpackagingrespectivelyaftertheinstallationof100S-BTstuds
Section4comprisestheinstructionsforuse(IFU)oftheS-BTstudswithadetailed
illustrationhowtousetheS-DGdepthgaugeandtheS-CCcalibrationcard.The
installerisresponsibleforthecorrectsettingoftheS-BTstuds.Fortheperiodical
vericationofthecorrectstudstandofftheS-CGBTcheckgaugecanbeused.
ThelifetimeoftheS-DGBTdepthgaugeis≥1000settings.
HiltiUCDSFC22-A(cordless)
Designandfunctionalityofthe
mechanical calibration card S-CC BT
6)%7$
D
E
F
6)%7$
76%76
6)&$
6'*%70:/RQJ
6'*%70/RQJ
6'*%70:/RQJ
6&&%7
D
616&ö 0
616
&ö:
616&ö0
616&ö0
616
&ö:
 PP
õ
 PP

 PP



PP


PP



1P
IWOE
7RUTXHWRRO;%7õ
1PIWOE
6%70)0$1
6%70):$1
6%70)0$1
6%70)0$1
6%70):$1
E
6)&$
6)&$
F
1P
6)&$
$
$

6%70)000
6%70)::


D
E
[

[
+H[QXWZLWKIODQJH0)
+H[QXWZLWKIODQJH:)
+H[QXWZLWKIODQJH0)
+H[QXWZLWKIODQJH0)
+H[QXWZLWKIODQJH:)
6'*%70:/RQJ
6'*%70/RQJ
6'*%70:/RQJ
Designandfunctionalityof
thecheckgaugeS-CGBT
S-DGBTmechanicaldepthgauge