ELECTRICAL CONNECTIONS
08 hinkley.com
REMEMBER -Turn o° the power! NOTE - Control must be installed within 30 feet of fan.
Use the wire nuts supplied with your fan when making connections. Secure the connectors with electrical tape and make sure there are no loose connections or wire
strands.
Insert the receiver into the ceiling mounting bracket with the ˝at side of the
receiver facing the ceiling. (Fig. 1) For best performance, make sure the Black
Antenna, on the end of the receiver, remains extended and not tangled with
any of the electrical wires.
Make wire connections from the fan to the receiver unit. For this
step use the bundle of 5 wires on the receiver. (Fig. 2)
Connect the YELLOW fan wire to the YELLOW receiver wire.
Connect the GRAY fan wire to the GRAY receiver wire.
Connect the RED fan neutral wire to the RED receiver neutral wire.
Connect the WHITE fan neutral wire to the WHITE receiver neutral wire.
Connect the BLUE fan neutral wire to the BLUE receiver neutral wire.
Connect the wiring from the ceiling to the receiver unit. (Use the 2 wire
bundle on the receiver.) Secure with supplied wire nuts.
Connect the BLACK building supply wire to the BLACK receiver wire.
Connect the WHITE receiver neutral wire to the WHITE building neutral
wire.
Connect the COPPER building ground wire to the YELLOW/GREEN fan
ground wire. Also connect the two GREEN wires (from fan) to building
ground wire.
|
Fig. 2
Fig. 1
Receiver
Hanger
bracket
Receiver
Fan
Outlet box
Ceiling
WH (AC IN)
GRN
GRN
GROUND
GRN (downrod)
GRN (hanger bracket)
WH
BLK
BLK (AC IN)
YELLOW/GRN
ORANGE(to motor)
GRAY (to motor)
YELLOW (to motor)
ORANGE (motor)
GRAY (motor)
YELLOW (motor)
1
2
3
NOTE:
One fan per power circuit.