Operation Manual

07-5
Rules for the mains connection:
Use only a 3 x 2.5 mm
2
cable with a maximum
length of 25 m, a CEE plug and connector to
connect the camper to an external 230 V
mains.
If the mains operates via a cable
drum, this must be completely
unwound, as otherwise induction may
cause the cable to heat up and burn.
If a residual current operated device (special
installations) has been installed in your cam-
per, it must be checked regularly by activating
the test button.
The 230 V mains connection in the camper
has been designed for a total power
consumption of 2300 W. If additional devices
requiring electricity are connected, such as
water heaters, etc., you must ensure that this
electric power value is not exceeded, taking
other electrical equipment into account that is
in use, e.g. refrigerator, therme, etc.
Assignment of fuses for power
supply
Fuses are assigned as follows (from left to right):
1st circuit 1 / 15A
2nd circuit 2 / 15A
3rd circuit 3 / 15A
4th circuit 4 / 15A
5th circuit 5 / 7.5A for water supply, oven, etc.
6th circuit 6 / 15A for the charge controller, not
via cut-off relay (not for 400 VA power supply)