Operation Manual

08-4
To remove water:
The water will be mixed to the desired
temperature according to the position of the
pre-mixing unit.
Emptying the therme:
Switch off the electricity for the water pump
by pressing the control panel (3) of the main
switch for 5 seconds.
Open all faucets.
Set all pre-mixing valves to "warm" if neces-
sary.
Open the runoff valve (4).
Check to see if water runs out.
Close the runoff valve (4) after emptying (if
necessary, blow the line out).
Electric operation:
Use the control panel (see 7.2) to switch on
the therme. The temperature of the water is
regulated to 55° C by means of a thermostat.
Power consumption: 300 W.
Rules for the therme:
Use the control panel to switch off this equip-
ment whenever the camper is not in use.
Empty the therme at the risk of frost. Frozen
water can cause the therme to burst!
A depressuriser must be used if the pump is
connected to a central water supply, or on
stronger pumps. The pressure in the therme
may not exceed 1.2 bar. In addition, a safety
valve or runoff valve (1) must be used in the
cold water tap.
We recommend that you do not use the water
from the therme as drinking water.
Never operate the therme electrically
when it is empty.
WARNING:
The block circuit diagram only reects the func-
tion. Due to the various oor plans, individual
modications are possible.
2
1
3
4
Plan for warm water supply