Operation Manual
08-4
To remove water:
• The water will be mixed to the desired
temperature according to the position of the
pre-mixing unit.
Emptying the therme:
• Switch off the electricity for the water pump
by pressing the control panel (3) of the main
switch for 5 seconds.
• Open all faucets.
• Set all pre-mixing valves to "warm" if neces-
sary.
• Open the runoff valve (4).
• Check to see if water runs out.
• Close the runoff valve (4) after emptying (if
necessary, blow the line out).
Electric operation:
• Use the control panel (see 7.2) to switch on
the therme. The temperature of the water is
regulated to 55° C by means of a thermostat.
• Power consumption: 300 W.
Rules for the therme:
• Use the control panel to switch off this equip-
ment whenever the camper is not in use.
• Empty the therme at the risk of frost. Frozen
water can cause the therme to burst!
• A depressuriser must be used if the pump is
connected to a central water supply, or on
stronger pumps. The pressure in the therme
may not exceed 1.2 bar. In addition, a safety
valve or runoff valve (1) must be used in the
cold water tap.
• We recommend that you do not use the water
from the therme as drinking water.
Never operate the therme electrically
when it is empty.
WARNING:
The block circuit diagram only reects the func-
tion. Due to the various oor plans, individual
modications are possible.
2
1
3
4
Plan for warm water supply