9.4 Hot-air heating with integrated boiler
(only in 460 LU Excellent)
Heating while driving is forbidden.
The Combi 4 LPG heating is a hot-air heating
system with an integrated hot-water boiler (con-
tents: 10 l).
It is possible to operate the heating system both
with and without water.
Location
In the left single bed behind the washroom.
Initial operation
Set the air exit nozzle in the camper so that
the hot air exits where you want it to.
Check that the ue is unobstructed. Any co-
vers must always be removed.
Open the gas bottle and the gas shutoff spi-
gots.
Operating device
a) knob for room temperature (1-5)
b) green LED shines: “in operation”
green LED blinks:
“return water” has been activated to reduce
the temperature of the device
c) operating in summer
(water temperature 40° C or 60° C)
d) operating in winter
(heating without controlled water temperature
or with empty water system)
e) operating in winter
(heating with controlled water temperature)
f) knob is “Off”
g) yellow LED shines: “boiler is in warm-up pha-
se”
h) red LED shines, red LED blinks:
“Malfunction” - take XXXXX and carefully cle-