Operation Manual

09-11
Filling the boiler
Close the drain valve by pressing on the but-
ton until it locks in place.
Turn on the 12 V power supply by means of
the main switch on the control panel.
Open all of the faucets and set them to “hot”.
Leave them open until the boiler has been
lled by displacement of the air.
If the temperature is below approx.
7° C, turn the heating on rst to heat
up the installation space and the
FrostControl on the drain valve. After
a few minutes, when the temperature
at the FrostControl is above 7° C,
you can close the drain valve.
Emptying the boiler
Turn off the 12 V power supply by means of
the control panel.
Open the hot water faucets.
Give the switch on the drain valve a 180° turn
until it locks in place (the button will pop out),
the drain valve opens and the contents of the
boiler are emptied outside.
Hot-water heating system
(optional; not part of standard delivery)
The Compact 3010 LPG heater is a hot-water
heating system which heats hot water separately
(contents: 8.5 l). It is possible to heat up the he-
ating system without lling the hot-water heater
with fresh water.
Location
In the wardrobe (except in the Landhaus
model).
Heating while driving is forbidden.