User Manual

60 SERIES I NDICATORS
40
1. Press [TARGET] or [F2]. Prompt = “Print ID’s?”.
2. Press [CLR/NO]. Prompt = “Clear One?”.
3. Press [ENTER]. Prompt = “ID to Delet”.
4. Key in the ID number to be deleted and press [ENTER].
5. If the ID number is not stored in the database, “Not Found” will be
displayed briefly. The indicator returns to the weigh mode.
6. Otherwise, if the ID number was found “Done” will be displayed
briefly and the indicator will return to the weigh mode.
CLEAR ALL
Clears all records from the database.
1. Press [TARGET] or [F2]. Prompt = “Print ID’s?”.
2. Press [CLR/NO]. Prompt = “Clear One?”.
3. Press [CLR/NO]. Prompt = “Clear ALL?”.
4. Press [ENTER]. Prompt = “Clear Sure?”.
5. Press [ENTER] indicator returns to previous display mode.
Note: [CLR] will abort the process.
STORE TRUCK IN TARE WEIGHT
Make a permanent record in the database for a truck tare weight.
1. Press [F1]. Prompt = “KeyIn ID#”.
2. Press [TARE]. Prompt = “Press tare or KeyIn”.
3. Key-In tare weight of truck or have truck on the scale.
4. Press [TARE]. Prompt = “KeyIn ID#”.
5. Key in the ID number and press [ENTER].