User Manual

60 SERIES I NDICATORS
48
P205 will appear in the “Custom Setup” list for each receive port enabled.
For example, if the receive mode is enabled for all four ports, the list will
display
P205—, P205˜, P205™, and P205š.
P240 – Minimum Transmit Width
A weight value that cannot be displayed due to the 6-digit limitation of the
standard VF display may not be printed. To ensure this is not possible, P240
must be set to a width of not greater than 7 (6 digits and a decimal point).
NTEP must also be enabled at P440. Any weight value that exceeds the
minimum width specified will be printed as dashes "-------".
P440 – NTEP Enable
P440 appears in the “Custom Setup” list if disabled. Refer to Enabling
NTEP Operation on page 46 for possible implications.
P9990 – Macro Instance Selection
P9990 appears in the “Custom Setup” list if at least one macro is configured.
Macro operation should be checked to verify its conformance to all
regulations.
ADDITIONAL CONFORMANCE CONSIDERATIONS
Several parameters must be considered on an individual basis as their
configuration may vary with different applications. These parameters
include, but are not limited to those listed in Table 5.
Table 5: Additional Conformance Parameters
PARAMETER DESCRIPTION COMMENT
P110 Full Scale Capacity Verify proper scale capacity.
P111 Division Size Verify allowable scale divisions.
P112 Zero Track Verify required selection.
P114 Motion Verify required selection.
P118 Zero Range Verify required selection.
P212 Print Stability Verify required selection.
P126 Æ P130 Multi-Range Verify proper configuration.
P151 Æ P154 Custom Units Verify name and conversion factor.
P600 Æ P646 Rename Parameters Verify acceptable names.