Correct wiring of the electrical service box, GFCI box and pack terminal block is required. Your spa requires a 4-wire, 40 or 50 amp
(depending on the spa model), 230 volt subfeed in non metallic pipe to the spa equipment compartment.
The black and red wires from the electrical box must be connected to the input of the GFCI.
The white wire from the electrical box must be connected to the neutral bus.
The green or copper wire must be connected to the ground lug of the GFCI.
The black, red and white wires going to the spa must be connected directly to the output of the GFCI.
The neutral to the GFCI must be connected to the neutral bus.
The green or copper wire going to the spa must be connected to the ground lug.
Hard wire the spa controls following the model specic diagram inside spa control box lid. The spa controls are inside the access
panels labeled “REMOVE THIS PANEL FOR ELECTRICAL”. In most models, the panel is underneath the spa’s top side control pad.
Electrical Requirements and Recommendations
DANGER!
Risk of Electrocution
Number of
Pumps
Voltage Breaker Connection
1 120V 20 amp Plug In
1 240V 40 amp Hard Wired
2 240V 50 amp Hard Wired
3 240V 50 amp Hard Wired
Electric Service Requirements