Powering on Your Spa
After lling the spa through the lter assembly to the correct level remove the water hose, replace the lter, the lter basket assembly
and the lter cover. Turn the GFCI on. Every time the GFCI is powered on, your spa controls run diagnostic tests. During diagnostic
testing, a series of messages are displayed on the topside controls. When diagnostic testing is complete, the spa begins priming mode.
Priming Mode
Each time you ll your spa some air may be trapped in the plumbing lines. Priming mode safely removes the air. To prevent failure, the
heater is disabled during priming mode. Pumps should be observed one at a time. Your spa will automatically begin normal heating and
ltering when priming is complete. Priming mode lasts approximately 5 minutes.
Run Pumps to Purge the Air
When this message is displayed on your topside controls, push the “Pump 1” button once to start the pump on low speed.
Press the “Pump 1” button a second time to switch to high speed. After conrming water is coming from all jets and the pump
is not surging, press the “Pump 1” button to turn the pump o.
Pump 2 is a single speed pump. Press the “Pump 2” button once to start Pump 2. After conrming water is coming from all
jets and the pump is not surging, press the “Pump 2” button to turn the pump o.
If the spa you purchased has 3 pumps, Pump 3 is a single speed pump. Press the “Pump 3” button to start Pump 3. After
conrming water is coming from all jets and the pump is not surging, press the “Pump 3” button to turn the pump o.
Within 2 minutes of pressing each pump button, water should be owing from the jets in every seat without surging. If none of the jets
in a seat work or if water surges, turn the pump o. After the water is completely still, repeat the process a second time. If the pumps
do not prime within 2 minutes on your second attempt, turn the GFCI o. Make sure the slice valves are locked in the OPEN position,
that the diverter valves are centered for even distribution of the water, that jets without ow are rotated to the open position and remove
any debris in the lter basket and on suction drain covers. Power the GFCI on and repeat the process to run each pump on HIGH
SPEED. If the pumps don’t prime on the third attempt, call 844-894-6659 for assistance.
Do not turn on any pump that will not prime. A pump that fails to prime should not be left on for more than 2 minutes under any
circumstance. The heater will engage when priming mode is complete. If a pump is not properly primed when the heater engages, the
spa may overheat causing serious damage.