Use and Care Manual

For technical support and assistance, call 844-894-6659
29
Programming Filtration Cycle Settings
Your spa is pre-programmed to lter once each day for 2 hours.
When the ltration cycle begins, all pumps will turn on and operate on HIGH SPEED to purge the lines and shut down automatically.
When purging is complete, Pump 1 will start on LOW SPEED and will automatically shut down when ltration cycle is complete.
During ltration cycles, the water circulates to remove debris and small particulates.
Increasing ltration will not eliminate or reduce the need for chemical sanitization.
How long your water needs to lter varies on a number of factors including how often the spa is used, for how long, and by how
many people. In addition to the ltration cycle, the water circulates every 30 minutes for diagnostic testing and during clean up cycles
that begin automatically 30 minutes after a pump button is pressed. Under normal use, adequate ltration should be achieved in two
hours. If the spa is used for longer periods by more bathers it may be necessary to increase the duration of your ltration cycle which
should not exceed 4 hours. Excessive ltration in may cause overheating. Your spa is pre-programmed to run one ltration cycle
every day for two hours. You can program when the ltration cycle will begin and the duration. Settings can be adjusted in 15 minute
intervals.
To program ltration cycles, press the “Temp” button, Wile the display is ashing, repeatedly press the “Light” button until
“FLTR” is displayed on the topside controls. Press the “Temp” button. While “BEGN” is ashing on the display, press and
hold the “Temp” button until the correct hour is displayed. Press the “Light” button to save the hour and move to minutes.
Press and hold the “Temp button until the desired 1/4 hour is displayed. Press the “Light” button. While “RUN HRS” is
ashing press and hold the “Temp” button until the desired number of hours is displayed. Press the “Light” button to save
the selection and move to minutes. Press and hold the “Temp” button until the correct 1/4 hour is displayed. Press the
“Light” button to save the selection and display the time of day the ltration cycle will end. Press the “Temp” button to
save the selection.
When selecting the start time pay close attention to “A” or “P” in the bottom right corner of the display. The ltration cycle will run
during the AM if “A” is displayed or PM if “P” is displayed. The system calculates the end time, so “A” or “P” are not included in that
display.