CONTROLLER OUTPUTS
The Omni II provides 8 programmable hardwired voltage outputs and two horn voltage outputs. These outputs are programmable
for the following output types:
General Purpose low voltage switching applications (12 VDC) - Units 65 - 72
Sounder triggering (a trigger for siren and voice drivers for BURG and FIRE)
Communicator outputs (radio, cellular, or any other type of auxiliary communicator)
'ARMED' and 'OK TO ARM' outputs
Switched Output (to power smoke detectors and cycle power to latching devices)
Outputs 1 - 8
can supply a maximum of 100 mA each. These outputs are included in the total DEVICES load, which cannot
exceed 1A.
If the Interior or Exterior Sounder is configured to an Output Type, the HORN outputs can supply a maximum of
1A. HORN outputs are included in the total HORNS load, which can not exceed 1A.
RESET OUTPUTS
Outputs 1-8 are protected from an overload condition. If an overload condition occurs on an output, it will shut off (the output
will supply 0V). When this occurs, the "Output Fault" (D26) LED (marked "A" if Figure 8) will illuminate. To reset the output,
remove the device causing the overload condition, then press the "Reset Outputs" (S1) Switch (marked "B" if Figure 8).
A
B
FIGURE 8 - RESETTING CONTROLLER OUTPUTS
OUTPUT APPLICATIONS
GENERAL PURPOSE SWITCHING APPLICATIONS
This output will supply 12 VDC to the output terminal when its corresponding unit is ON. Output 1 is designated Unit 65 through
Output 8 which is Unit 72. This can be used to drive relays for many different applications, including switching sprinkler valves
and low-voltage lighting.
SOUNDER TRIGGERING
This output can be used as a trigger for siren and voice drivers. When a driver requires a separate input for burglary and fire, you
can configure this output to give a voltage trigger to the driver. Also, each area can have its own sounder.