- HAI (Home Automation Inc.) Home Security System User Manual

Page 44
To enable or change a thermostat type, press the ' # ' key. Use the arrow keys to scroll through the list of thermostat types, then
press ' # ' to select a new type
. The display shows:
SELECT TYPE: 1
AUTO HEAT/COOL
TYPE NUMBER DESCRIPTION
AUTO HEAT/COOL 1 Automatic changeover heat and cool thermostat
HEAT/COOL 2 Manual changeover heat and cool thermostat
HEAT ONLY 3 Heating only thermostat
COOL ONLY 4 Cooling only thermostat
SETPOINT ONLY 5 Setpoint only thermostat
SETUP MISCELLANEOUS
To configure the miscellaneous Installer Setup items, from the Installer Setup menu, press the 6 (MISC) key.
INSTALLER CODE
The Installer code allows the installer access to the Installer Setup menu. The Installer code should be changed and not given to
the customer. The Installer code cannot be used for remote phone access.
INSTALLER CODE:
0000-9999 0000=DISABLE
The default setting for the Installer code is 1 1 1 1.
NOTE:
Remember this Installer code and do not disable. There is no way to reset or retrieve the code! If the code is forgotten or
disabled, the Omni II controller must be sent back to the factory. Call for an RA#.
ENABLE PC ACCESS
This enables or disables the PC ACCESS feature. Factory default is enabled.
ENABLE PC ACCESS: 1
0=NO 1=YES
PC ACCESS CODE
This code allows dealers to put an access code in the system that is separate from the customer's Master code and the Installer
code. Dealers can use the PC Access code to access the system by PC. The PC Access code cannot arm and disarm the system.
The PC Access code is NOT programmed from the factory. To use it, set it to any code other than 0000. To disable the PC
Access code, enter 0000 for the code.
NOTE: This item must be enabled (by entering a code) if PC Access is will be used.
PC ACCESS CODE:
0000-9999 0000=DISABLE