Page 49
SETUP EXPANSION
To configure each Expansion Module that is installed on your system, from the Installer Setup menu, press the 7 (EXP) key.
Expansion Modules include Hardwire Zone Expanders, ALC Interface Modules, and Serial Interface Modules using either the
Omni-Link or Pro-Link Protocol.
MODULE 1 TYPE
The Module Type defines the function of each expansion module on the controller. Module 1 is the module with the ADDR
jumper set to 1. Set the module type from the list below. Press ' # ' to change the module type, then use the arrow keys to select
the proper module type, then press ' # ' to enter.
MODULE 1 TYPE 1
NOT USED #=CHNG
Select from the following for the module with jumper set to 1:
MODULE TYPES NUMBER DESCRIPTION
NOT USED 0 No module is installed
HARDWIRE EXPNDR 1 Model 10A06 Hardwire Expander installed
ALC 2 ALC Interface Module is installed
OMNI-LINK 3 Model 10A17 Serial Interface using the Omni-Link protocol
PRO-LINK 4 Model 10A17 Serial Interface using the Pro-Link protocol
Notes:
1. Only 2 Model 10A06 Hardwire Expander Modules can be installed. When a Wireless Receiver is configured, only 1
Hardwire Expander Module can be installed.
2. Only 1 Serial Interface Module can be installed and configured (Omni-Link or Pro-Link). To configure the protocol for the
built-in serial port, set the "Serial 1 Function" to the desired protocol.
MODULE 2 TYPE - MODULE 4 TYPE
Module 2 is the module with the jumper set to 2, and so on. Set each module type from the list above.
SERIAL 1 RATE
"Serial 1 Rate" selects the baud rate used for the built-in serial interface (J1 Serial) on the Omni II controller. Select the baud rate
for the built-in serial interface from the list. Use the arrow keys to select the baud rate then press the ' # ' key.
BAUD RATE NUMBER
75 baud 1
150 baud 2
300 baud 3
600 baud 4
1200 baud 5
2400 baud 6
4800 baud 7
9600 baud 8 (default)