SDS

SAMSUNG SDI Co., Ltd.
Date: January 1
st
2020 Revision no.: 01
MODEL: INR21700-40T
Page 15 of 24
chromium(III) oxide)(OECD TG 405, GLP)
- Lithium carbonate;Lithane : In the eye irritation test using rabbit, the test material was moderately
irritating. (OECD Guideline 405, GLP)
- Ethylbenzene : In test on eyes irritation with rabbits, slight irritations were observed to rabbit.
Respiratory sensitization : Not classified
- Aluminum : Al2O3 was the least inflammatory material tested and led to only weak effects on the
mouse lung. (Read across; Aluminium oxide)
- Boehmite (Al(OH)O) : In respiratory sensitization test with mice, it did not induce respiratory
sensitization.
- Carbon black : In respiratory sensitization test with mice, it did not induce respiratory sensitization.
Skin sensitization :
- Graphite : In the skin sensitization test using mice, the test material was not skin sensitization.
(OECD Guideline 429, GLP)
- Fe : In the test using guinea pigs, the test substance was not considered to be a dermal sensitizer in
guinea pigs.(read across; FeO, Fe2O3)
- Copper : In maximization test on skin sensitization with guinea pig, skin sensitization was not
observed. (OECD TG 406, GLP)
- Aluminum : In test with guinea pigs, it can be concluded that aluminium oxide has no sensitisation
potential under the experimental conditions. (Read across; Aluminium oxide)
- Lithium hexafluorophosphate(1-) : In the skin sensitization test using mice, the test material was not
skin sensitization. (OECD Guideline 429, GLP)
- 4-fluoro-1,3-dioxolan-2-one : In the skin sensitization test using mice, the test material was skin
sensitization. (OECD Guideline 429, GLP)
- Dimethyl carbonate : In the skin sensitization test using guinea pig, this material was not skin
sensitizing. (OECD Guideline 406, GLP)
- Polyethylene : No reactions were observed in skin sensitization test with guinea pigs.
- Diiron trioxide : In the skin sensitization test using guinea pigs, the test material was not skin
sensitizing.
- Boehmite (Al(OH)O) : In the skin sensitization test using guinea pig, this material was not skin
sensitizing.(OECD Guideline 406, GLP)
- Carbon black : In skin sensitization test with guinea pig, it did not induce skin sensitization. (OECD
TG 406, GLP)
- Nickel; Raney nickel : Nickel hypersensitivity dermatitis may be initiated by contact with nickel on the
skin.
- 1-Methyl-2-pyrrolidinone : In the skin sensitization test using mice, the test material was not skin
sensitization. (OECD Guideline 429, GLP)
- Chromium : In vitro skin sensitisation test, the test substance was not considered to be a dermal
sensitizer.
- Lithium carbonate;Lithane : In the skin sensitization test using guinea pig, this material was not skin
sensitizing. (OECD Guideline 406, GLP)
Carcinogenicity :
IARC
- Nickel : Group 2B
- Cobalt and cobalt compounds : Group 2B
- Polyethylene : Group 3
- diiron trioxide : Group 3
- Carbon black : Group 2B
- Chromium : Group 3
- Ethylbenzene : Group 2B
NTP
- Nickel : R
- Iron : Present