SDS

SAMSUNG SDI Co., Ltd.
Date: January 1
st
2020 Revision no.: 01
MODEL: INR21700-40T
Page 7 of 24
- Cover with Dry earth, DRY sand or other non-combustible material and put on the plastic sheet to
minimize spreading or contact with rain.
- Move battery to well ventilated area to prevent gas accumulation.
- Dispose in accordance with applicable local, state and federal regulations.
Other information: Not available
6.4 Reference to other sections
- See also sections 8 and 13 of the Safety Data Sheet.
Section VII HANDLING AND STORAGE
7.1 Precautions for safe handling
- In case of cell damage, possible release of dangerous substances and a flammable gas mixture.
- The battery stores electrical energy and is capable of rapid energy discharge.
- Battery cell contents are under pressure.
- Handle battery carefully to avoid puncturing case or electrically shorting terminals.
7.2 Conditions for safe storage, including any incompatibilities
Technical measures and storage conditions : Not available
Packaging materials : Not available
Requirements for storage rooms and vessels :
- Storage at room temperature (approx. 20) at approx. 40% of the nominal capacity
- Keep in closed original container.
7.3 Specific end use(s)
Recommendations : Not available
Industrial sector specific solutions : Not available
Section VIII EXPOSURE CONTROLS / PERSONAL PROTECTION
8.1 Control parameters
Occupational Exposure limits
Name
ACGIH
regulation
Biological
exposure index
OSHA
regulation
NIOSH
regulation
EU regulation
Lithium Nickel Oxide
TWA = 1.5 mg/m³
(inhalable
particulate
matter)(Nickel
CAS.no 7440-02-
0)
Not available
TWA = 1 mg/m³
(metal and
insoluble
compounds (as
Ni))
TWA = 1 mg/m³
(soluble
Ca TWA =
0.015 mg/m
3
(metal and
insoluble
compounds (as
Ni))
Ca TWA =
Not applicable