SDS

Safety Data Sheet
29 CFR 1910.1200
Effective Date 26/05-2015
Trade Name Alkaline Manganese Dry Battery
6 Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Wear protective equipment. Keep unprotected persons away.
Environmental precautions: Do not allow to enter sewers/surface or ground water.
Methods and material for containment and cleaning up:
Use neutralizing agent.
Dispose contaminated material as waste according to item 13.
Ensure adequate ventilation.
7 Handling and storage
Precautions for safe handling:
Thorough dedusting.
Ensure good ventilation/exhaustion at the workplace.
Information about protection against explosions and fires: No special measures required.
Storage
Conditions for safe storage, including any incompatibilities
Requirements to be met by storerooms and receptacles: No special requirements.
Information about storage in one common storage facility: Not required.
Further information about storage conditions: Keep receptacle tightly sealed.
Specific end use(s): No further relevant information available.
8 Exposure controls / personal protection
Components with limit values that require monitoring at the workplace:
1313-13-9 manganese dioxide (42.0-45.0%)
PEL (USA)
Ceiling limit value: 5mg/m
3
as Mn
REL (USA)
Short-term value: 3mg/m
3
Long-term value: 1mg/m
3
as Mn
TLV (USA)
Long-term value: 0.02*0.1* mg/m
3
as Mn* respirable **inhalable fraction
1310-58-3 potassium hydroxiede (6.0-7.0%)
REL (USA)
Ceiling limit value: 2mg/m
3
TLV(USA)
Ceiling limit value: 2mg/m
3
7440-50-8 copper (1.0-3.5%)
PEL (USA)
Long-term value: 1*0.1**mg/m
3
as Cu *dusts and mists **fume
REL (USA)
Long-term value: 1*0.1**mg/m
3
as Cu *dusts and mists **fume
TLV(USA)
Long-term value: 1*0.2**mg/m
3
*dusts and mists **fume; as Cu
7782-42-5 Graphite (2.0-3.0%)
PEL (USA)
Long-term value: 15mppcf*mg/m
3
(Contd. on page 5)
(Contd. on page 3)