Installation Guide

9
HOME-FLEX® Appliance Connectors
2.11 HOME-FLEX® Appliance Connectors
HOME-FLEX® CSST cannot be used to make direct connections to moveable appliances like
gas ranges or clothes dryers (see Section 4.6 on page 29). Connection to these appliances
should be made from a HOME-FLEX® Termination Flange tting to a HOME-FLEX® Appliance
Connector, or comparable device. Appliance connectors are available coated and uncoated
in lengths of 12, 18, 24, 30, 36, 48, 60 and 72 inches with a variety of end ttings. Browse
the full product line at homeex.com. Determine the correct appliance connector for your
application by identifying the required length to connect the gas outlet to the appliance inlet
and select the series that oers a maximum ow rate greater than the maximum demand of
the appliance.
Length
Maximum Flow Rate (CFH) by Series
HFHC
3/8" OD
1/4" ID
HFDC
1/2" OD
3/8" ID
HFRC
5/8" OD
1/2" ID
HFSA
1" OD
3/4" ID
12" 52,400 117,750 192,000 481,250
18" 49,900 110,975 181,400 458,925
24" 47,400 104,200 170,800 436,600
30" 44,900 97,425 160,200 414,275
36" 42,400 90,650 149,600 391,950
48" 37,400 77,100 128,400 347,300
60" 34,250 70,950 116,650 323,850
72" 31,100 64,800 104,900 300,400