Installation Guide

16
Installation Practices
after the pressure / leak test has been completed (see Section “4.4 Pressure and Leak Testing”
on page 18) and the system has passed inspection by the local authority having jurisdiction
(AHJ).
4.3 Fitting Assembly Overview
HOME-FLEX Underground® IPS ttings are for use with IPS sized yellow poly gas pipe
that has been approved for use with natural gas and propane.
Body Flange
NutNut
Stiener
Tubing
Step 1 Check contents
Each product package includes a tting
and a number of stieners to be used on
each end of pipe being connected (i.e. 2
stieners for a Coupler or Elbow, 3 for a Tee).
Step 2 Cut the pipe square
There is no need to chamfer the pipe end.
Ensure any burrs on the pipe are removed
and the pipe is clean.
Step 3 Insert stieners
Insert the supplied stieners into each end
of the pipe being connected.