PART NO. 18127-C Printed in U.S.A. PORTABLE SPACE HEATER OWNER’S MANUAL 50 SIDE PFA/PV 010A 100 SIDE FRONT HANDLES PFA/PV 003 Models: HHC35A, HHC100A, and HHC150A IMPORTANT Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
CONTENTS SECTION PAGE Safety Information ......................................................................... 3 Product Identification .................................................................... 4 Unpacking ...................................................................................... 5 Assembly ....................................................................................... 5 35 Model ..................................................................................
SAFETY INFORMATION IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from fire, explosion, electrical shock, and carbon monoxide poisoning. Read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater. ! WARNINGS WARNING ICON G 001 • Use only kerosene or No. 1 fuel oil.
PRODUCT IDENTIFICATION Nose Cone Guard Hot Air Outlet Upper Shell Handle Fan Guard Lower Shell Air Filter End Cover Fuel Tank Fuel Cap Side Cover Flame-Out Control Reset Button 35/70,000 BTU/HR CANADIAN PFA/PV 042A Power Cord Figure 1 - 35 Model Hot Air Outlet Upper Shell Lower Shell Fuel Cap Fan Guard Fuel Tank Side Cover Power Cord Flame-Out Control Reset Button Figure 2 - 100/150 Models 4 100577
UNPACKING ASSEMBLY (For 35 Model Only) 1. Remove all protective packaging that has been applied to heater for shipment 2. Remove heater from carton. 3. Check heater for any shipping damage. If damage is found, promptly inform dealer where heater was purchased. This model is furnished with a nose cone guard. Nose cone guard and mounting screws are found in the shipping carton. Tools Needed • 5/16" Nut Driver or Wrench 1. Place nose cone guard on top of upper shell flange.
ASSEMBLY (For 100 and 150 Models Only) These models are furnished with wheels and a front handle. Wheels, front handle, and the mounting hardware is found in the shipping carton. Tools Needed • Medium Phillips Screwdriver • 3/8" Open or Adjustable Wrench • Hammer 1. Slide axle through wheel support frame. Install wheels on axle. IMPORTANT: Place extended hub of wheel toward wheel support frame. 2. Place cap nuts on axle ends. Gently tap with hammer to secure. 3.
The Fuel System: An air pump is located on one end of the motor shaft. The air pump forces air through the air line. The air is then pushed through the burner head nozzle. The moving air causes fuel to be lifted from the tank. The fuel and air mixture is sprayed into the combustion chamber in a fine mist. THEORY OF OPERATION The Air System: The motor turns a fan which pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.
FUELS ! WARNING Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, crankcase drainings, naphtha, paint thinners, alcohol, or other highly flammable fuels. Use only kerosene or No. 1 fuel oil. Do not use heavy fuels such as No. 2 fuel oil or No. 2 diesel. The use of heavy fuels will result in: • clogging of fuel filter and nozzle • carbon build up on spark plug • the need of non-toxic anti-icer in fuel during very cold weather Do not use No.
4. Plug heater’s power cord into approved, grounded, three-wire extension cord. Extension cord must be at least six feet (1.8 meters) long. Extension Cord Size Requirement 6 to 10 feet (1.8 to 3 meters) long, use 18 AWG (0.75 mm2) rated cord 11 to 100 feet (3.3 to 30.5 meters) long, use 16 AWG (1.0 mm2) rated cord 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm2) rated cord 5. Plug extension cord into standard 120 volt/60 hertz, 3-prong grounded outlet.
STORING, TRANSPORTING, OR SHIPPING Note: If shipping, transport companies require fuel tanks to be empty. 1. Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed. 2. Replace drain plug if provided. 3. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again.
TROUBLESHOOTING ! WARNING To avoid risk of burn and electrical shock, never attempt to service heater while it is plugged in, operating, or hot. OBSERVED FAULT Heater ignites, but flame-out control shuts off heater after a short period of time. POSSIBLE CAUSE Incorrect pump pressure REMEDY See Pump Pressure Adjustment, page 13. Dirty air output, air intake and lint filters See Air Output, Air Intake and Lint Filters, page 12. Dirty fuel filter See Fuel Filter, page 13.
SERVICE PROCEDURES ! WARNING To avoid risk of burn and electrical shock, never attempt to service heater while it is plugged in, operating or hot. Upper Shell Upper Shell Removal 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. 2. Lift upper shell off. 3. Remove fan guard. Fan Guard Figure 8 - Upper Shell Removal (35 Model Shown) Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater.
Pump Pressure Adjustment 1. Remove pressure gauge plug from filter end cover. 2. Install accessory pressure gauge (part number 00529-02). 3. Start heater (see Operation, page 8). Allow motor to reach full speed. 4. Adjust pressure. Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. See specifications at right for correct pressure for each model. 5. Remove pressure gauge. Replace pressure gauge plug in filter end cover.
Spark Plug (35 Model) 1. Remove upper shell (see page 12). 2. Remove fan (see page 12). 3. Remove fuel and air line hoses from nozzle assembly. 4. Remove spark plug cable from spark plug. 5. Remove two (2) screws using 5/16" nut-driver and remove burner strap. 6. Place hex-body of spark plug into vise and tighten. 7. Remove spark plug mounting nut using 11/16" open-end wrench. 8. Remove burner strap from spark plug. 9. Clean and regap spark plug electrodes to .055" (1.4 mm) gap. 10.
Combustion Chamber Nozzle (35 Model) 1. Remove upper shell (see page 12). 2. Remove fan (see page 12). 3. Remove fuel and air line hoses from nozzle assembly. 4. Turn nozzle assembly 1/4 turn to left and pull toward motor to remove. 5. Place plastic hex-body into vise and lightly tighten. 6. Carefully remove nozzle from the nozzle adapter using 5/8" socket wrench. 7. Blow compressed air through face of nozzle. This will free any dirt in nozzle area. 8. Inspect nozzle seal for damage. 9.
Nozzle Face 12. Attach burner head to combustion chamber. 13. Install spark plug in burner head. 14. Attach spark plug cable to spark plug. 15. Attach fuel and airline hoses to burner head. 16. Replace fan (see page 12). 17. Replace fan guard and upper shell. Nozzle Seal Nozzle Burner Head Fuel Line Air Line Fitting Fitting Figure 26 - Removing Nozzle, 100/150 Models Blade Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 12). 2.
13.Perform steps 1 through 6 (see page 16). 14.Place fine grade sandpaper (600 grit) on flat surface. Sand rotor lightly in “Figure 8” motion four times (see Figure 30). 15.Reinstall insert and rotor. 16.Perform steps 10 through 12 (see page 16). Gap Adjusting Screw .003"/.004" (.076-.
WIRING DIAGRAMS Power Plug 120V/60Hz White Black Green White White White Green Motor Blue Blue Ignitor Spark Plug Terminal White Board Red Red B FlameOut Control Reset Button Photocell R Red Figure 31 - Wiring Diagram, 35 Model Power Plug 120V/60Hz Black Green White White White White Green Motor Ignitor Spark Plug Terminal Board Red White Red Blue Blue Photocell B FlameOut Control Reset Button R Red Black Relay Red Figure 32 - Wiring Diagram, 100/150 Models 18 100577
ACCESSORIES Heater accessories and parts are available at your local dealer. AIR GAUGE KIT For all models. Special tool to check pump pressure. Order part number 00529-02. THERMOSTAT KIT For all models. Keeps your building at the temperature you select day and night. Helps economize on fuel. Order part number 01145-58. THERMOSTAT A 011 HEAVY DUTY WHEELS AND HANDLE KIT For heavy duty applications. HEAVYeven DUTY WHEELS Makes your heater more & HANDLE KIT portable and convenient. Fits 35 model.
HOMELITE 1850 55TH Avenue Lachine (Quebec) H8T 3J5 Unit 212-214 590 Ebury Place Annacis Island New Westminister, B.C. V3M 6K7 595 Canarctic Drive Downsview, Ontario M3J 2P9 A Deere & Co. Affiliate / Une Filiale de Deere & Co.
Pièce no. 18127-C Imprimé aux É-U CHAUFFERETTE PORTATIVE GUIDE DU PROPRIETAIRE 50 SIDE PFA/PV 010A 100 SIDE FRONT HANDLES PFA/PV 003 Modèles: HHC35A, HHC100A, et HHC150A IMPORTANT Assurez-vous d’avoir lu et compris ce guide avant de commencer à monter, utiliser ou réparer cet appareil. Une mauvaise utilisation de cet appareil pourrait causer des blessures graves. Gardez ce guide pour vous y reporter plus tard.
TABLE DES MATIERES INDEX PAGE Notes sur la sécurité ....................................................................... 3 Nomenclature des pièces principales ............................................. 4 Déballage ....................................................................................... 5 Montage ......................................................................................... 5 Modèle 35 ...............................................................................
NOTES SUR LA SECURITE IMPORTANT: Vous devez lire ce guide attentivement et complètement avant de commencer à monter, faire fonctionner, ou réparer cet appareil. Sa mauvaise utilisation pourrait causer des blessures graves ou la mort par incendie, explosion, chocs électriques et asphyxie par l’oxyde de carbone. Assurez-vous de lire et de comprendre tous les avertissements. Gardez ce guide à portée de la main. Il vous aidera à faire fonctionner votre appareil de chauffage en toute sécurité.
NOMENCLATURE DES PIECES PRINCIPALES Barre de protection Sortie d’air chaud Couvercle Poignée Grille de protection du ventilateur Boîtier Cache-filtre Réservoir de combustible Bouchon du réservoir de combustible Plaque amovible Bouton de remise en service 35/70,000 BTU/HR CANADIAN PFA/PV 042A Cordon électrique Figure 1 - Modèle 35 Sortie d’air chaud Couvercle Boîtier Bouchon du réservoir de combustible Grille de protection du ventilateur Réservoir de combustible Plaque amovible Bouton de remi
DEBALLAGE MONTAGE (Pour le modèle 35 seulement) 1. Retirez tous les emballages de protection utilisés pour le transport. 2. Retirez l’appareil de la boîte. 3. Vérifiez l’état de l’appareil. S’il est endommagé, avertissez immédiatement le concessionnaire qui vous l’a vendu. Cet modèle livré avec une barre de protection. Cette barre se trouve, avec ses vis de montage, dans la boîte d’emballage. Outillage nécessaire • Clé plate ou tourne-écrous de 5/16 po 1.
MONTAGE (pour les modèles 100 et 150 seulement) Ces modèles sont livrés avec des roues et un guidon pour la partie avant. Les roues et le guidon se trouvent dans la boîte d’emballage. Outillage nécessaire • Tournevis cruciforme de taille moyenne • Clé plate ou clé à molette de 3/8 po • Marteau 1. Faites passer l’axe au travers des alésages du berceau. Installez les roues sur l’axe. IMPORTANT: Installez les roues avec les moyeux tournés vers le berceau. 2. Engagez un capuchon sur chaque bout de l’axe.
PRINCIPES DE FONCTIONNEMENT Circuit de combustion: Une pompe à air montée sur l’arbre arrière du moteur refoule l’air vers l’avant et le fait passer sur la buse du brûleur. La dépression causée par l’air fait monter le combustible du réservoir et le mélange se vaporise dans la chambre de combustion. Circuit d’air: Un ventilateur monté sur le moteur fait circuler l’air dans la chambre de combustion et autour. Cet air y est chauffé pour produire un jet d’air chaud et propre.
COMBUSTIBLES ! AVERTISSEMENT Pour éviter les risques d’incendie ou d’explosion utilisez seulement du kérosène ou du mazout n° 1. Ne vous servez jamais d’essence, d’huile de vidange, de naphte, de diluant à peinture, d’alcool, ou de tout autre combustible très inflammable. Utilisez seulement du kérosène ou du mazout n° 1. N’utilisez pas d’huile lourde comme le mazout n° 2 ou le carburant diesel n° 2.
4. Branchez le cordon électrique à une rallonge à trois fils avec mise à la terre. La rallonge doit avoir une longueur d’au moins 1,8 m (6 pi). Conditions requises pour les rallonges électriques Pour les longueurs de 1,8 à 3 m (6 à 10 pi), rallonge de calibre 18 (0,75 mm) De 3,3 à 30,5 m (de 11 à 100 pi), rallonge de calibre 16 (1 mm) De 30,8 à 61 m (101 à 200 pi), rallonge de calibre 14 (1,5 mm) 5. Branchez la rallonge à une prise standard de 120 volts/60 hertz avec prise de terre.
ENTREPOSAGE, TRANSPORT OU EXPÉDITION CALENDRIER D’ENTRETIEN 10 Remarque: les sociétés de transport exigent que les réservoirs de combustible soient vides pour l’expédition. 1. Vidanger le réservoir de combustible. Remarque: certains modèles sont équipés d’un bouchon de vidange au-dessous du réservoir. Le cas échéant, le retirer pour vidanger le réservoir. Si l’appareil de chauffage n’en est pas équipé, vidanger le réservoir par l’orifice de remplissage. Veiller à vider complètement le réservoir. 2.
DIAGNOSTIC DES PANNES ! AVERTISSEMENT Pour éviter les risques de brûlure et de chocs électriques, n’effectuez aucune opération d’entretien sur l’appareil de chauffage lorsqu’il est branché, fonctionne, ou est chaud. ANOMALIE L’appareil s’allume mais le dispositif de sécurité l’arrête après une courte période de temps.
ENTRETIEN MARCHE A SUIVRE ! AVERTISSEMENT Pour éviter les risques de brûlure et de chocs électriques, n’effectuez aucune opération d’entretien sur l’appareil lorsqu’il est branché, fonctionne, ou est chaud. Démontage du couvercle Couvercle 1. En se servant d’un tourne-écrou de 5/16 po, retirez les vis qui se trouvent de chaque côté du couvercle. Ces vis retiennent le couvercle sur le boîtier. 2. Levez le couvercle. 3. Retirez la grille de protection du ventilateur.
4. Remplacez les filtres de sortie d’air et à poussière (voir Calendrier d’entretien, page 10). 5. Lavez ou remplacez le filtre d’entrée d’air (voir Calendrier d’entretien, page 10). 6. Remontez le cache-filtre. 7. Remontez la grille de protection du ventilateur et le couvercle. IMPORTANT: Ne pas huiler les filtres. (Modèle 35 seulement) Figure 13 - Dépose du bouchon fileté Manomètre Réglage de la pression de la pompe 1. Retirez le bouchon fileté qui se trouve sur le cache-filtre. 2.
Bougie (modèle 35) 1. Déposez le couvercle (voir page 12). 2. Déposez le ventilateur (voir page12). 3. Détachez les conduites de combustible et d’air du porte-buse. 4. Débranchez le fil de la bougie. 5. Avec un tourne-écrou de 5/16 po déposez les deux vis qui retiennent la bride de montage du brûleur. 6. Serrez la tête hexagonale de la bougie dans un étau. 7. Avec une clé plate de 11/16 po déposez l’écrou de montage de la bougie. 8. Retirez la bougie de la bride de montage du brûleur. 9.
Bougie (modèles 100/150) Brûleur 1. Déposez le couvercle (voir page 12). 2. Déposez le ventilateur (voir page 12). 3. Débranchez le fil de la bougie. 4. Avec une clé plate de 13/16 po déposez la bougie du brûleur. 5. Nettoyez les électrodes de la bougie et réglez leur écartement comme suit: Modèle 100 = 1,4 mm (0,055 po) Modèle 150 = 1,9 mm (0,075 po) 6. Reposez la bougie sur le brûleur. 7. Rebranchez le fil de la bougie. 8. Reposez le ventilateur (voir page 12). 9.
Buse (modèles 100/150) 1. Déposez le couvercle (voir page 12). 2. Déposez le ventilateur (voir page 12). 3. Déposez les conduites d’arrivée de combustible et d’air du brûleur. 4. Détachez le fil de la bougie. 5. Déposez la bougie du brûleur avec une clé plate de 13/16 po. 6. Avec un tourne-écrou de 5/16 po déposez trois vis du brûleur et retirez-le de la chambre de combustion. 7. Serrez légèrement le brûleur dans un étau. 8.
Palette Rotor de la pompe (Marche à suivre en cas de grippage) Couvercle de la pompe Filtre d’entrée d’air 1. Déposez le couvercle (voir page 12). 2. Avec un tourne-écrou de 5/16 po déposez les vis du cachefiltre. 3. Retirez le cache-filtre et les filtres à air. 4. Avec un tourne-écrou de 5/16 po déposez les vis de fixation du couvercle de la pompe. 5. Déposez le couvercle de la pompe. 6. Déposez le rotor, la pièce noyée et les palettes. 7. Assurez-vous qu’il n’y a pas de corps étrangers dans la pompe.
FICHE TECHNIQUE Numéro de modèle Rendement (Btu/h) Combustible Contenance du réservoir (litres/gal U.S.
ACCESSOIRES Votre concessionnaire peut vous fournir les accessoires et les pièces détachées pour cet appareil de chauffage. MANOMETRE Pour tous les modèles. Sert à vérifier la pression de la-pompe. Commander la pièce n° 00529-02. THERMOSTAT Pour tous les modèles. Aide à maintenir une température constante jour et nuit et économise le combustible. Commander la pièce n° 01145-58. THERMOSTAT A 011 ROUES ET GUIDON POUR TRAVAIL INTENSIF Améliore la maniabilité et la portabilité de l’appareil.
HOMELITE 1850 55TH Avenue Lachine (Quebec) H8T 3J5 Unit 212-214 590 Ebury Place Annacis Island New Westminister, B.C. V3M 6K7 595 Canarctic Drive Downsview, Ontario M3J 2P9 A Deere & Co. Affiliate / Une Filiale de Deere & Co.