Operation Manual

17
MAINTENANCE
To ensure that the generating set performs correctly and has a long working life, it is essential
that the maintenance schedule be observed.
CAUTION :
The engine and the muffler reach temperatures sufficient to cause burns if touched and to
start a fire if adjacent to inflammable material. Allow the engine to cool for 15 minutes
before carrying out any maintenance.
Only use original Honda parts. Parts that do not meet the Honda design specifications
can cause damage to the generating set.
MAINTENANCE SCHEDULE
NOTE:
(1) Clean more often if used in a dusty environment.
(2) These operations must be carried out by a Honda dealer, unless the user has the
special tools necessary and is qualified to do the work.
INTERVAL
Maintenance to be carried out at the intervals
shown either in months or in hours of use,
whichever comes first.
On
each
use
During the
1st month
or after 20
hours
Every
3 months
or 50
hours
Every
6 months
or 100
hours
Every
year
or 300
hours
Maintenance item Action
Engine oil
Check level
Change
Air cleaner element
Check
Clean
(1)
Sediment cup Clean
Spark plug Clean - Adjust
Combustion chamber and valves Clean
(2)
Valve clearance Clean - Adjust
(2)
Fuel tank and filter Clean
(2)
Fuel line
Check -
Replace if
necessary
Spark arrester
ECM2800 Clean
(2)
ECMT7000
Check
Clean
SAFETY
SAFETY
5 7
ANGLAIS.book Page 17 Lundi, 18. février 2008 11:11 11