31Z07610 00X31-Z07-6100 EU2000i Black DIC F101 Owner’s Manual GENERATOR EU2000i 31Z07610 00X31-Z07-6100 2eY110000.2006.12 Printed in Japan o2001-2006 Honda Motor Co., Ltd.
06/12/21 09:16:55 31Z07602_001 The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death. Never run the generator in a closed or even partially closed area where people may be present. The generator is a potential source of electrical shock if misused.
06/12/21 09:12:29 31Z07602_002 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. As you read this manual, you will find information preceded by a symbol.
A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others. Of course, it is not practical or possible to warn you about all the hazards associated with operating or maintaining a generator.
06/12/21 09:12:34 31Z07602_004 CONTENTS GENERATOR SAFETY ............................................................................... 5 Safety Label Locations ........................................................................ 5 Important Safety Information ............................................................. 7 COMPONENT IDENTIFICATION ............................................................... 9 CONTROLS .................................................................................
06/12/21 09:12:37 31Z07602_005 MAINTENANCE ....................................................................................... 36 The Importance of Maintenance ....................................................... 36 Maintenance Safety ........................................................................... 37 Emission Control System Information ............................................. 38 Air Index ..............................................................................................
06/12/21 09:17:03 31Z07602_006 GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda generator dealer for a replacement.
6
06/12/21 09:17:11 31Z07602_008 IMPORTANT SAFETY INFORMATION Honda generators are designed to give safe and dependable service if operated according to instructions. Read and understand this owner’s manual before operating your generator. You can help prevent accidents by being familiar with your generator’s controls, and by observing safe operating procedures. Operator Responsibility Know how to stop the generator quickly in case of emergency.
06/12/21 09:17:22 31Z07602_009 Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry. If the generator is stored outdoors, unprotected from the weather, check all of the electrical components on the control panel before each use.
06/12/21 09:12:43 31Z07602_010 COMPONENT IDENTIFICATION PARALLEL OPERATION OUTLETS ECO-THROTTLETM SWITCH AC RECEPTACLES OIL ALERT INDICATOR LIGHT OVERLOAD INDICATOR LIGHT DC RECEPTACLE OUTPUT INDICATOR LIGHT DC CIRCUIT PROTECTOR AC CIRCUIT PROTECTOR GROUND TERMINAL FUEL TANK CAP VENT LEVER CHOKE LEVER FUEL TANK CAP MAINTENANCE COVER STARTER GRIP ENGINE SWITCH 9
06/12/21 09:12:49 31Z07602_011 SPARK PLUG MAINTENANCE COVER SPARK PLUG MUFFLER FRAME SERIAL NUMBER AIR CLEANER Record the frame serial number for your future reference. Refer to this serial number when ordering parts, and when making technical or warranty inquiries (see page 62 ).
06/12/21 09:12:58 31Z07602_012 CONTROLS ENGINE SWITCH To start and stop the engine. Switch position: OFF: To stop the engine. ON: To start and run the engine. ENGINE SWITCH ON OFF STARTER GRIP To start the engine, pull the starter grip lightly until you feel resistance, then pull briskly in the direction of the arrow as shown below. Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter.
06/12/21 09:13:08 31Z07602_013 FUEL TANK CAP VENT LEVER The fuel tank cap is provided with a vent lever to seal the fuel tank. The vent lever must be in the ON position for the engine to run. When the engine is not in use, leave the vent lever in the OFF position to reduce the possibility of fuel leakage. Allow the engine to cool well before turning the vent lever to the OFF position.
OUTPUT INDICATOR LIGHT The output indicator light (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. OUTPUT INDICATOR LIGHT (GREEN) OVERLOAD INDICATOR LIGHT If the generator is overloaded (in excess of 2,000 VA), or if there is a short circuit in a connected appliance, the overload indicator light (red) will go ON.
06/12/21 09:13:17 31Z07602_015 OIL ALERT SYSTEM The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert indicator light comes on and the Oil Alert system automatically will stop the engine (the engine switch will remain in the ON position).
06/12/21 09:13:27 31Z07602_016 ECO-THROTTLETM SWITCH The Eco-ThrottleTM system automatically reduces engine speed when all loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. If high electrical loads are connected simultaneously, turn the EcoThrottle switch to the OFF position to reduce voltage changes. When using the DC output, turn the Eco-Throttle switch to the OFF position.
06/12/21 09:17:33 31Z07602_017 AC CIRCUIT PROTECTOR The AC circuit protector will automatically switch OFF if there is a short circuit or a significant overload of the generator at the AC receptacles. If the circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the circuit protector ON.
05/12/26 17:07:15 31Z07602_018 GENERATOR USE CONNECTIONS TO A BUILDING ELECTRICAL SYSTEM Connections for standby power to a building electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. Improper connections to a building electrical system can allow electrical current from the generator to backfeed into the utility lines.
06/12/21 09:17:38 31Z07602_019 SPECIAL REQUIREMENTS Keep all cooling holes open and clear of debris, mud, water, etc. Cooling holes are located on the side panel, the control panel, and the bottom of the generator. If the cooling holes are blocked, the generator may overheat and damage the engine, inverter, or windings. Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property.
AC APPLICATIONS Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance, or if the rated load capacity of the generator has been exceeded.
AC OPERATION 1. Start the engine and make sure the output indicator light (green) comes on (see page 33 ). 2. Plug in the appliance. Most motorized appliances require more than their rated wattage for startup. OVERLOAD INDICATOR LIGHT (RED) OUTPUT INDICATOR LIGHT (GREEN) If the generator is overloaded (in excess of 2,000 VA), or if there is a short circuit in a connected appliance, the overload indicator light (red) will go ON.
AC PARALLEL OPERATION APPLICATIONS Follow the instructions included with the parallel operation kit. Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately.
Limit operation requiring maximum power to 30 minutes. Maximum power in parallel operation is: 4.0 kVA For continuous operation, do not exceed the rated power. Rated power in parallel operation is: 3.2 kVA The total power requirements (VA) of all appliances connected must be considered. Appliance and power tool manufacturers usually list rating information near the model number or serial number.
AC PARALLEL OPERATION 1. Connect the parallel operation kit between the two EU2000i generators following the instructions supplied with the kit. PARALLEL OPERATION KIT (optional equipment) 2. Start the generators and make sure the output indicator lights (green) come on (see page 33). 3. Plug in the appliance following the instructions provided with the parallel operation kit. Most motorized appliances require more than their rated wattage for startup.
06/12/21 09:13:37 31Z07602_025 DC OPERATION The DC receptacle should ONLY be used for charging 12-volt automotive type batteries. The DC charging output is not regulated. When using the DC output, turn the Eco-Throttle switch to the OFF position. Connecting the battery charging cable (optional equipment): 1. Before connecting the battery charging cable to a battery that is installed in a vehicle, disconnect the vehicle battery ground cable from the negative ( ) battery terminal.
Do not start the vehicle while the battery charging cable is connected and the generator is running. The vehicle or the generator may be damaged. An overloaded DC circuit, excessive current draw by the battery, or a wiring problem will trip the DC circuit protector (PUSH button extends out). If this happens, wait a few minutes before pushing in the circuit protector to resume operation. If the DC circuit protector continues to go OFF, discontinue charging and see your authorized Honda generator dealer.
06/12/21 09:13:45 31Z07602_027 ECO-THROTTLETM SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned OFF or disconnected. When appliances are turned ON or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the EcoThrottleTM system does not operate. Appliances with large start-up power demands may not allow the engine to reach normal operating rpm when they are connected to the generator.
HIGH ALTITUDE OPERATION At high altitude, the standard carburetor air/fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions. High altitude performance can be improved by specific modifications to the carburetor.
06/12/21 09:15:57 31Z07602_029 PRE-OPERATION CHECK ENGINE OIL Check the oil level BEFORE EACH USE with the generator on a level surface and the engine stopped. Use 4-stroke motor oil that meets or exceeds the requirements for API service classification SJ or later (or equivalent). Always check the API SERVICE label on the oil container to be sure it includes the letter SJ or later (or equivalent). SAE VISCOSITY GRADES AMBIENT TEMPERATURE SAE 10W-30 is recommended for general, all-temperature use.
06/12/21 09:17:43 31Z07602_030 3. Remove the oil filler cap and wipe the dipstick clean. 4. Check the oil level by inserting the dipstick into the filler neck without screwing it in. 5. If the level is low, fill to the upper limit of the oil filler neck with the recommended oil. 6. Reinstall the maintenance cover and tighten the cover screw securely.
06/12/21 09:16:05 31Z07602_031 REFUELING With the engine stopped, remove the fuel tank cap and check the fuel level. Refill the fuel tank if the fuel level is low. Refuel carefully to avoid spilling fuel. Do not fill above the upper limit mark. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. Stop the engine and keep heat, sparks, and flame away. Handle fuel only outdoors. Wipe up spills immediately. Fuel can damage paint and plastic.
06/12/21 09:16:10 31Z07602_032 CALIFORNIA TYPE FUEL TANK CAP UPPER LIMIT MARK TETHER After refueling, tighten the fuel cap until it clicks.
06/12/21 09:16:16 31Z07602_033 FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher. Never use stale or contaminated gasoline or an oil/gasoline mixture. Avoid getting dirt or water in the fuel tank. You may use regular unleaded gasoline containing no more than 10% Ethanol (E10) or 5% Methanol by volume. In addition, Methanol must contain cosolvents and corrosion inhibitors.
06/12/21 09:19:03 31Z07602_034 STARTING THE ENGINE STARTING THE ENGINE For your safety, avoid starting or operating the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death. Carbon monoxide gas is toxic. Breathing it can cause unconsciousness and even kill you. Avoid any enclosed areas, partially enclosed areas or activities that may expose you to carbon monoxide. 1.
06/12/21 09:19:08 31Z07602_035 7. If the choke lever was moved to the CLOSED position to start the engine, gradually move it to the OPEN position as the engine warms up. 8. If you wish to use the Eco-Throttle system, turn the Eco-Throttle switch to the ON position after the engine has warmed up for 2 or 3 minutes. 9. Refer to the AC OPERATION (see page 20 ) or DC OPERATION (see page 24 ) for connecting loads to the generator.
06/12/21 09:19:17 31Z07602_036 STOPPING THE ENGINE STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure. 1. Unplug appliances from the generator receptacles. 2. Turn the engine switch to the OFF position. The fuel valve will automatically close. 3. Allow the engine to cool well, turn the vent lever to the OFF position. 4.
06/12/21 09:19:24 31Z07602_037 MAINTENANCE THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and trouble free operation. It will also help reduce air pollution. Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously hurt or killed. Always follow the inspection and maintenance recommendations and schedules in this owner’s manual.
06/12/21 09:19:33 31Z07602_038 MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Failure to properly follow maintenance instructions and precautions can cause you to be seriously hurt or killed. Always follow the procedures and precautions in the owner’s manual.
06/12/21 09:19:42 31Z07602_039 EMISSION CONTROL SYSTEM INFORMATION Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen are very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
06/12/21 09:19:49 31Z07602_040 Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your servicing dealer. Hard starting or stalling after starting. Rough idle. Misfiring or backfiring under load. Afterburning (backfiring). Black exhaust smoke or high fuel consumption.
06/12/21 09:20:01 31Z07602_041 AIR INDEX (Models certified for sale in California) An Air Index Information hang tag/label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines. The lower the Air Index, the less pollution.
06/12/21 09:20:13 31Z07602_042 MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD (3) ITEM Perform at every indicated month or o per ati ng h our int erv al, whichever comes first. Engine oil Check level Change Air cleaner Check Clean Spark plug Check-adjust Replace Spark arrester Clean Valve clearance Check-readjust Combustion chamber Clean Fuel tank and filter Clean Fuel line Check Each use First month or 20 hrs. Every Every Every 3 months 6 months year or or or 50 hrs. 100 hrs. 200 hrs.
06/12/21 09:20:22 31Z07602_043 ENGINE OIL CHANGE Drain the used oil while the engine is warm. Warm oil drains quickly and completely. 1. Turn the engine switch and vent lever to the OFF position to reduce the possibility of fuel leakage. 2. Loosen the cover screw and remove the maintenance cover (see page 28 ). 3. Place a suitable container next to the engine to catch the used oil. 4. Remove the oil filler cap/dipstick, and drain the oil into the container by tipping the engine toward the oil filler neck.
06/12/21 09:20:26 31Z07602_044 Wash your hands with soap and water after handling used oil. Improper disposal of engine oil can be harmful to the environment. If you change your own oil, please dispose of it properly. Put it in a sealed container, and take it to a recycling center. Do not discard it in a trash bin, dump it on the ground, or pour it down a drain.
06/12/21 09:20:37 31Z07602_045 AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. Using gasoline or flammable solvent to clean the air filter can cause a fire or explosion. Use only soapy water or nonflammable solvent.
06/12/21 09:20:42 31Z07602_046 5. Reinstall the air filters. 6. Make sure that the rubber seal is set in the groove of the air cleaner cover. 7. Reinstall the air cleaner cover, and tighten the air cleaner cover screw. RUBBER SEAL 8. Reinstall the maintenance cover, and tighten the cover screw securely.
06/12/21 09:20:53 31Z07602_047 SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plug: CR5HSB (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage. If the engine has been running, allow it to cool before servicing the spark plug. 1. Remove the spark plug maintenance cover. SPARK PLUG MAINTENANCE COVER SPARK PLUG CAP 2.
06/12/21 09:21:02 31Z07602_048 5. Visually inspect the spark plug. Replace it if the electrodes are worn or if the insulator is cracked, chipped, or fouled. 6. Measure the spark plug electrode gap with a wire-type feeler gauge. Correct the gap, if necessary, by carefully bending the side electrode. The gap should be: 0.024 0.028 in (0.60 0.70 mm) 0.024 0.028 in (0.60 0.70 mm) SEALING WASHER 7.
06/12/21 09:21:11 31Z07602_049 SPARK ARRESTER MAINTENANCE If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding. The spark arrester must be serviced every 100 hours to maintain its efficiency. Clean the spark arrester as follows: 1. Remove the four 6 mm screws, and remove the muffler protector. MUFFLER PROTECTOR 6 mm SCREWS 2. Remove the three 6 mm bolts, and remove the muffler, the spark arrester, and the muffler gasket.
06/12/21 09:21:15 31Z07602_050 3. Use a brush to remove carbon deposits from the spark arrester screen. 4. Inspect the screen for breaks or tears and replace it if necessary. 5. Check the muffler gasket; replace if damaged. Reinstall the muffler gasket, the spark arrester, the muffler, and the muffler protector in the reverse order of removal.
06/12/21 09:21:21 31Z07602_051 TRANSPORTING/STORAGE TRANSPORTING Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property. If the generator has been used, allow it cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some material.
06/12/21 09:21:27 31Z07602_052 STORAGE Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust. 2. Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required Fill with fresh gasoline and add gasoline 1 to 2 months stabilizer . Run the engine for 10 minutes to use up the non-treated gasoline. Fill with fresh gasoline and add gasoline 2 to 6 months stabilizer .
06/12/21 09:21:34 31Z07602_053 Storage Procedure 1. Drain the gasoline. a. Unscrew the fuel tank cap, remove the debris screen, and empty the fuel tank into an approved gasoline container using a commercially available hand siphon. Reinstall the debris screen and the fuel tank cap. b. Loosen the cover screw and remove the maintenance cover. c. Loosen the carburetor drain screw. d. Drain the gasoline from the carburetor into a suitable container. e. Remove the spark plug maintenance cover. f.
06/12/21 09:21:38 31Z07602_054 2. Change the engine oil (see page 42). 3. Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug. 4. Reinstall the spark plug cap on the spark plug securely. 5. Reinstall the spark plug maintenance cover. 6. Reinstall the maintenance cover and tighten the cover screw securely. 7.
06/12/21 09:21:43 31Z07602_055 TROUBLESHOOTING When the engine will not start: NO Is there fuel in the tank? Refill the fuel tank (see page 30). YES Is there enough oil NO in the engine? Add the recommended oil (see page 28). YES Is the spark plug in NO good condition? YES If the engine still does not start, take the generator to an authorized Honda generator dealer. 54 Clean, readjust gap, and dry the spark plug. Replace it if necessary (see page 46).
06/12/21 09:21:50 31Z07602_056 Appliance does not operate: Is the output indicator light ON? (see page 13) YES NO Is the overload indicator light ON? (see page 13) NO Take the generator to an authorized Honda generator dealer. YES NO DEFECTS Take the generator to an authorized Honda generator dealer. Check the electrical appliance or equipment for any defects. DEFECTS Replace the electrical appliance or equipment. Take the electrical appliance or equipment to an electrical shop for repair.
06/12/21 09:22:11 31Z07602_057 WIRING DIAGRAM 56
06/12/21 09:22:22 31Z07602_058 INITIAL USE INSTRUCTIONS ADDING ENGINE OIL The generator is shipped WITHOUT OIL in the engine. 1. Place the generator on a level surface. 2. Loosen the cover screw and remove the maintenance cover. COVER SCREW MAINTENANCE COVER 3. With the generator in a level position, remove the oil filler cap/ dipstick. 4. Add enough SAE 10W-30 API service classification SJ or later (or equivalent) oil to bring the oil level to the upper limit of the oil filler neck.
06/12/21 09:22:32 31Z07602_059 ADDING FUEL This engine is certified to operate on unleaded gasoline with a pump octane rating of 86 or higher. Never use stale or contaminated gasoline or an oil/gasoline mixture. Avoid getting dirt or water in the fuel tank. If the fuel level is low, refuel in a well-ventilated area with the engine stopped. If the engine has been running, allow it to cool first. Never refuel the engine inside a building where gasoline fumes can reach flames or sparks.
06/12/21 09:22:40 31Z07602_060 1. Remove the fuel tank cap. NON-CALIFORNIA TYPE FUEL TANK CAP CALIFORNIA TYPE FUEL TANK CAP 2. Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper limit mark on the fuel strainer. NON-CALIFORNIA TYPE UPPER LIMIT MARK CALIFORNIA TYPE UPPER LIMIT MARK TETHER Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank. Damage caused by spilled fuel is not covered under warranty.
06/12/21 09:22:49 31Z07602_061 3. After refueling, tighten the fuel cap securely (Non-California type). After refueling, tighten the fuel cap until it clicks (California type). Keep the vent OFF for storage or transport, and ON to run the generator. NON-CALIFORNIA TYPE CALIFORNIA TYPE OFF OFF ON ON VENT LEVER VENT LEVER Move the generator at least 10 feet (3 meters) away from the fueling source and site before starting the engine.
06/12/21 09:23:04 31Z07602_062 SPECIFICATIONS Dimensions Model Description code Length Width Height Dry weight EU2000i EAAJ 20.2 in (512 mm) 11.4 in (290 mm) 16.7 in (425 mm) 45.9 lbs (20.8 kg) Engine Model Engine type Displacement Bore Stroke Compression ratio Engine speed Cooling system Ignition system Oil capacity Fuel tank capacity Spark plug GX100 4-stroke, overhead camshaft, single cylinder 6.01 cu-in (98.5 cm ) 2.20 1.57 in (56.0 8.5: 1 40.
06/12/21 09:23:14 31Z07602_063 TECHNICAL & CONSUMER INFORMATION Dealer Locator Information To find an authorized Honda Servicing Dealer anywhere in the United States: Visit our website: www.hondapowerequipment.com Customer Service Information Servicing dealership personnel are trained professionals. They should be able to answer most questions you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management.
06/12/21 09:23:23 31Z07602_064 Honda Publications Shop Manual This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician. Available through your Honda dealer or through Helm Inc. at 1 888292-5395 or visit www.hondapowerequipment.com Parts Catalog This manual provides complete, illustrated parts lists. Available through your Honda dealer.
06/12/21 09:23:32 31Z07602_065 Distributor’s Limited Warranty PRODUCTS COVERED BY THIS WARRANTY EU series generators Engine Generator Electrical and Frame Components Parts & Accessories. LENGTH OF WARRANTY (from date of original retail purchase) Commercial/ Noncommercial/ Rental Nonrental 24 months 24 months 12 months 24 months See your authorized Honda servicing dealer for details To Qualify for this Warranty: The product must be purchased in the United States, Puerto Rico, or the U.S.
06/12/21 09:23:38 31Z07602_066 Exclusions: This warranty does not extend to parts affected or damaged by accident and/or collision, normal wear, fuel contamination, use in an application for which the product was not designed, or any other misuse, neglect, incorporation or use of unsuitable attachments or parts, unauthorized alteration, or any causes other than defects in material or workmanship of the product.
06/12/21 09:23:43 31Z07602_067 Other States, U.S. territories and Canada In other areas of the United States and in Canada, your engine must be designed, built, and equipped to meet the U.S. EPA and Environment Canada emission standards for spark-ignited engines at or below 19 kilowatts.
06/12/21 09:23:48 31Z07602_068 If you have any questions regarding your warranty rights and responsibilities, you should contact the Honda Office in your region: American Honda Motor Co., Inc. Power Equipment Customer Relations 4900 Marconi Drive Alpharetta, Georgia 30005-8847 Telephone: (770) 497-6400 or Honda Canada Inc.
06/12/21 09:23:51 31Z07602_069 To Obtain Warranty Service: You must take your Honda Power Equipment engine or the product on which it is installed, along with your sales registration card or other proof of original purchase date, at your expense, to any Honda Power Equipment dealer who is authorized by Honda to sell and service that Honda product during his normal business hours.
06/12/21 09:23:58 31Z07602_070 Disclaimer of Consequential Damage and Limitation of Implied Warranties: American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any responsibility for incidental or consequential damages such as loss of time or the use of the power equipment, or any commercial loss due to the failure of the equipment; and any implied warranties are limited to the duration of this written warranty. This warranty is applicable only where the California, U.S.
06/12/21 09:24:03 31Z07602_071 INDEX COMPONENT IDENTIFICATION ............................................................... 9 CONTENTS ................................................................................................. 3 CONTROLS ............................................................................................... 11 AC Circuit Protector ............................................................................ 16 Choke Lever .....................................................
06/12/21 09:24:06 31Z07602_072 MAINTENANCE ....................................................................................... 36 Air Cleaner Service ............................................................................ 44 Air Index .............................................................................................. 40 Emission Control System Information ............................................. 38 Engine Oil Change ..................................................................
06/12/21 09:24:07 31Z07602_073 MEMO 72
31Z07610 00X31-Z07-6100 EU2000i Black DIC F101 Owner’s Manual GENERATOR EU2000i 31Z07610 00X31-Z07-6100 2eY110000.2006.12 Printed in Japan o2001-2006 Honda Motor Co., Ltd.