Data Sheet

45
LLN Series
Industrial sensors
Features
Solid-state reliability
No moving parts
TTL - compatible - 200 mA sinking output; fast
response
Reverse polarity and overvoltage protection
Stainless-steel housing for long life and ease of
cleaning
Quick-connect, industry standard cable assembly for
easy installation
Wide operating temperature range (-40 °C to +125 °C)
Polysulphone sensor dome suitable for hygiene
applications
High pressure housing, rated up to 25 bars
High degree of sealing-IP67
CE certified
Description
LLN Series industrial liquid level sensors are designed for
industrial environments exposed to extremes of
temperature, pressure, vibration and shock. Standard
devices feature rugged stainless steel housings and
polysulphone domes.
The mode of operation is based on the same principal as
the LL series.
An internal regulator enables a supply voltage in the
range of 10-40 Vdc to be used while the output is capable
of sinking up to 200 mA.
Principle - in air
Typical applications
Industrial compressors
Machine tools
Material handling
Processing and packaging equipment
Heavy duty automotive
LED
Optoschmitt
Technical information
Specifications
Operation mode User defined single on/off switch
Repeatability (mm) ±1
Hysteresis (mm) 1 (Dependent on liquid)
Response time Rising liquid level - 50 us
Falling liquid level -1s max. (in ethanol)
Response in other liquids dependent on
viscosity
Mechanical
Mounting Exterior mounting by 3/8" B.S.P. thread
Connector 3-pin integral Lumberg/Brad Harrison type
connector
Pin 1 supply (V
cc
)
Pin 3 0 V
Pin 4 output
A range of cable/connector assemblies is
available
Material Polysulphone dome; stainless steel housing
(other materials available on request)
Dimensions Dome 3,5 mm radius
Thread 3/8" B.S.P.
Hex 24 mm
Environmental
Operating temperature (°C) -40 to 125 (Sensing end only)
Storage temperature (°C) -50 to +90
Humidity No effect on operation, dependent upon
catalogue listing
Vibration / shock Qualification tested 100 to 5000 Hz at 30g to
B.S.2011 part 2.1
Pressure range (bar) 0 - 25
Ambient light limit (mW/cm
2
) 0.5 in operation
Electrical
Supply Voltage (V
cc
) 10 to 40 Vdc
Reverse voltage protection to 40 Vdc
Short circuit protection to 40 Vdc
Supply current 60 mA max
Output sink current (I
0
) 200 mA max

Summary of content (3 pages)