10
sensing.honeywell.com
SX Series
MICRO SWITCH™ JX SERIES AUXILIARY ACTUATORS FOR THE MICRO SWITCH™ SX SERIES
SWITCHES (stainless steel actuators and hardware)
Description Actuator
length
Operting
Force
max.
Release
Force
min.
Pretravel
max.
Overtravel
min.
Differential
Travel max.
Operating
Point
approx.
Free
Position
ref.
JX-20
JX-219
Straight lever
(JX-219
for higher
temperatures)
18,3 mm
[0.72 in]***
0,28 N
[1 oz]
approx.
0,04 N
[0.14 oz]
0,76 mm
[0.030 in]
approx.
0,76 mm
[0.030 in]
approx.
10,8 mm
[0.425 in]
12,3 mm
[0.485 in]
JX-25
JX-220
Roller lever
(JX-220
for higher
temperatures)
16,5 mm
[0.65 in]***
0,42 N
[1.5 oz]
0,04 N
[0.14 oz]
0,51 mm
[0.020 in]
0,76 mm
[0.030 in]
14,9 ,mm
[0.585 in]
168 mm
[0.660 in]
JX-40
JX-95
Straight
leaf (JX-95
for higher
temperatures)
9,4 mm
[0.37 in]
D
1,95 N
[7 oz]
0,56 N
[2 oz]
5,7 mm
[0.225 in ]
approx.
0,38 mm
[0.015 in]
0,64mm
[0.025 in]
7,5 mm
[0.295 in]
12,3 mm
[0.485 in]
JX-41**
Reverse leaf 9,4 mm
[0.37 in]
D
1,67 N
[6 oz]
0,28 N
[1 oz]
2,79 mm
[0.110 in]
approx.
0,38 mm
[0.015 in]
0,64mm
[0.025 in]
7,5 mm
[0.295 in]
9,4 mm
[0.370 in]
JX-45
JX-96
Roller leaf
(JX-96 for
higher
temperatures)
6,1 mm
[0.24 in]
D
1,95 N
[7 oz]
0,28 N
[1 oz]]
5,7 mm
[0.225 in ]
approx.
0,38 mm
[0.015 in]
0,64mm
[0.025 in]
12,2 mm
[0.48 in]
16,5 mm
[0.650 in]
JX-51**
Reverse roller
leaf
7,6 mm
[0.30 in]
D
1,67 N
[6 oz]
0,56 N
[2 oz]
2,79 mm
[0.110 in]
approx.
0,38 mm
[0.015 in]
0,64mm
[0.025 in]
12,8 mm
[0.505 in]
14,7 mm
[0.58 in]
JX-4
Tandem leaf 7,9 mm
[0.31 in]
D
4,17 N
[15 oz]
0,83 N
[3 oz]
1,65 mm
[0.065 in]
approx.
0,20 mm
[0.008 in]
0,76 mm
[0.030 in]
7,6 mm
[0.30 in]
9,40 mm
[0.37 in]
** Switch is mounted with plunger end reversed from JX-40
NOTE: Above actuators should be used below 149 °C [300 °F], except listings JX-95, JX-96, JX-219, and JX-220 are for use
with 4SX1-T to 204 °C [400 °F]
D
Measurement for leaf-style levers is from center of mounting hole
nearest tip of lever to the point indicated on the drawing
*** Measurement for hinge-style levers is from pivot point of the lever
to the end of the lever or center of the lever’s roller
D
***