Datasheet

Commercial Thermostats
10 www.honeywell.com/sensing
Table 12. 2455RM/2450CM Series Specifications
Characteristic Parameter
Switch type SPST
Reset type manual
Amperage 15 A resistive at 6,000 cycles (UL); 16 A resistive at 1000 cycles (EU)
Voltage 120 Vac to 250 Vac
Operating temperature range 2455RM: 52 °C to 150 °C [125 °F to 302 °F]
2450CM: 52 °C to 232 °C [125 °F to 450 °F]
Environmental exposure range 2455RM: -20 °C to 177 °C [0 °F to 350 °F]
2450CM: -20 °C to 260 °C [0 °F to 500 °F]
Materials:
Base
Contacts
Terminals
Closure
Brackets
2455RM: phenolic; 2450CM: ceramic
silver alloy
2455RM: unplated brass, plated brass or steel; 2450CM: plated steel
aluminum, brass, or stainless steel
stainless steel
Approvals UL File E36103, CSA File LR21048
Weight 6 g [0.21 oz] (does not include brackets or wire leads)
NOTICE
2455RM/2450CM thermostats are intended as a manual reset control. They are not to be used on applications where a limit
thermostat is required unless back-up protection is provided. Units have been tested by UL for 1,000 cycles under load,
5,000 cycles no load, and are not considered as limit devices.
This range of thermostats has an automatic reset function with manual override function.
Reset pin operation should not be performed above 70% of set point temperature.
Table 13. 2450CM/2455RM Contact Ratings
Life Cycles 120 Vac 240 Vac
6,000 15 A resistive 10 A resistive
6,000 4.4 FLA 26.4 LRA
125 VA pilot duty
2.2 FLA 13.2 LRA
125 VA pilot duty
Note: Additional contact ratings are available, please consult Honeywell.
Figure 7. 2455RM/2455CM Basic Dimensions
2455RM
2450CM
A Maximum travel of reset button on contact opening
B On contact closing
C Reset button