Datasheet

Commercial Thermostats
12 www.honeywell.com/sensing
Table 15. 2455RD Series Specifications
Characteristic Parameter
Switch type SPST
Reset type manual
Amperage 15 A resistive at 6,000 cycles (UL); 16 A resistive at 1000 cycles (EU)
Voltage 120 Vac to 250 Vac
Operating temperature range 2455RD: 52 °C to 150 °C [125 °F to 302 °F]
Environmental exposure range 2455RD: -20 °C to 177 °C [0 °F to 350 °F]
Materials:
Base
Contacts
Terminals
Closure
Brackets
phenolic
silver alloy
unplated brass, plated brass or steel
aluminum, brass, or stainless steel
stainless steel
Approvals UL File E36103, CSA File LR21048
Table 16. 2455RD Contact Ratings
Life Cycles 120 Vac 240 Vac
6000 15 A resistive 10 A resistive
Note: Additional contact ratings are available, please consult Honeywell.
Figure 9. 2455RD Basic Dimensions
A Maximum travel of reset button on contact opening
B On contact closing
C Reset button