Datasheet

7
sensing.honeywell.com
Table 7. Pressure Range Specifications
Pressure
Range
(see Figure 3)
Pressure
Range
Unit Overpressure
1
Burst Pressure
2
Common Mode
Pressure
3
Total Error Band
4
(%FSS)
Long-term Stability
1000 hr, 25 °C
(%FSS)
Pmin. Pmax.
60 mbar to 10 bar
Differential
060MD -60 60 mbar 850 1000 10000 ±1.5 ±0.25
100MD -100 100 mbar 140 0 2500 10000 ±1.5 ±0.25
160MD -160 160 mbar 1400 2500 10000 ±1.5 ±0.25
250MD -250 250 mbar 1400 2500 10000 ±1.5 ±0.25
400MD -400 400 mbar 2000 4000 10000 ±1.5 ±0.25
600MD -600 600 mbar 2000 4000 10000 ±1.5 ±0.25
001BD -1 1 bar 4 8 10 ±1.5 ±0.25
1.6BD -1.6 1.6 bar 8 16 10 ±1.5 ±0.25
2.5BD -2.5 2.5 bar 8 16 10 ±1.5 ±0.25
004BD -4.0 4.0 bar 16 17 10 ±1.5 ±0.25
Gage
060MG 0 60 mbar 850 1000 5450 ±1.5 ±0.25
100MG 0 100 mbar 850 1000 10000 ±1.5 ±0.25
160MG 0 160 mbar 850 1000 10000 ±1.5 ±0.25
250MG 0 250 mbar 140 0 2500 10000 ±1.5 ±0.25
400MG 0 400 mbar 2000 4000 10000 ±1.5 ±0.25
600MG 0 600 mbar 2000 4000 10000 ±1.5 ±0.25
001BG 0 1 bar 2 4 10 ±1.5 ±0.25
1.6BG 0 1.6 bar 4 8 10 ±1.5 ±0.25
2.5BG 0 2.5 bar 8 16 10 ±1.5 ±0.25
004BG 0 4 bar 8 16 16 ±1.5 ±0.25
006BG 0 6 bar 17 17 17 ±1.5 ±0.25
010BG 0 10 bar 17 17 17 ±1.5 ±0.25
Pressure Range Specifications
6 kPa to 1 MPa
Differential
006KD -6 6 kPa 85 100 1000 ±1.5 ±0.25
010KD -10 10 kPa 140 250 1000 ±1.5 ±0.25
016KD -16 16 kPa 140 250 1000 ±1.5 ±0.25
025KD -25 25 kPa 140 250 1000 ±1.5 ±0.25
040KD -40 40 kPa 200 400 1000 ±1.5 ±0.25
060KD -60 60 kPa 200 400 1000 ±1.5 ±0.25
100KD -100 100 kPa 400 800 1000 ±1.5 ±0.25
160KD -160 160 kPa 800 1600 1000 ±1.5 ±0.25
250KD -250 250 kPa 800 1600 1000 ±1.5 ±0.25
400KD -400 400 kPa 1600 170 0 1000 ±1.5 ±0.25
Gage
006KG 0 6 kPa 85 100 545 ±1.5 ±0.25
010KG 0 10 kPa 85 100 1000 ±1.5 ±0.25
016KG 0 16 kPa 85 100 1000 ±1.5 ±0.25
025KG 0 25 kPa 140 250 1000 ±1.5 ±0.25
040KG 0 40 kPa 200 400 1000 ±1.5 ±0.25
060KG 0 60 kPa 200 400 1000 ±1.5 ±0.25
100KG 0 100 kPa 200 400 1000 ±1.5 ±0.25
160KG 0 160 kPa 400 800 1000 ±1.5 ±0.25
250KG 0 250 kPa 800 1600 1000 ±1.5 ±0.25
400KG 0 400 kPa 800 1600 1600 ±1.5 ±0.25
600KG 0 600 kPa 1700 1700 1700 ±1.5 ±0.25
001GG 0 1 MPa 1.7 1.7 1.7 ±1.5 ±0.25
1
Overpressure:Themaximumpressurewhichmaysafelybeappliedtotheproductforittoremaininspecificationoncepressureisreturnedtotheoperatingpressurerange.Exposure
tohigherpressuresmaycausepermanentdamagetotheproduct.Unlessotherwisespecifiedthisappliestoallavailablepressureportsatanytemperaturewiththeoperating
temperature range.
2
Burstpressure:Themaximumpressurethatmaybeappliedtoanyportoftheproductwithoutcausingescapeofpressuremedia.Productshould not be expected to function after
exposure to any pressure beyond the burst pressure.
3
Commonmodepressure:Themaximumpressurethatcanbeappliedsimultaneouslytobothportsofadifferentialpressuresensorwithoutcausingchangesinspecified
performance.
4
TotalErrorBand:Themaximumdeviationfromtheidealtransferfunctionovertheentirecompensatedtemperatureandpressurerange.Includesallerrorsduetooffset,fullscale
span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis.