notherm IV T8611G Instruction Manual

69-0936—1
4
T8611G CHRONOTHERM
®
IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
Fig. 6. T8611G key locations and descriptions.
Fig. 7. T8611G System and Fan key locations.
Table 2. Default Program Settings.
M15042
Hold Temp
Run
Program
Copy
Daylight
Time
Set Current
Day/Time
System Fan
Time Set Program
Day
System
Fan
Wake
Leave
Return
Sleep
Heat/Cool
Settings
Period Time
Heat
Setpoint
Cool
Setpoint
Fan
Setting
Wake 6:00 AM 70°F
(21°C)
78°F
(25.5°C)
Auto
Leave 8:00 AM 62°F
(16.5°C)
85°F
(29.5°C)
Auto
Return 6:00 PM 70°F
(21°C)
78°F
(25.5°C)
Auto
Sleep 10:00 PM 62°F
(16.5°C)
82°F
(28°C)
Auto
INSTALLER SETUP
NOTE: For most applications, the thermostat factory-
settings will not need to be changed. Review the
factory settings in Table 2 and if no changes are
necessary, go to the Installer System-Test
section.
The Installer Setup is used to customize the thermostat
to specific systems. Some of the options include
temperature display, changeover and outdoor
temperature display. Installer Setup numbers are listed in
Ta ble 3. The table includes all the configuration options
and the factory-settings for the T8611.
M10405
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
INCREASE TEMPERATURE
SETTING OR SCROLL
FORWARD THROUGH
INSTALLER SETUP OPTIONS
DECREASE TEMPERATURE
SETTING OR SCROLL
BACKWARD THROUGH
INSTALLER SETUP OPTIONS
DISPLAY INFORMATION
SUCH AS PRESENT
SETTINGS AND OUTDOOR
TEMPERATURE
RETURN TO
NORMAL
OPERATIONS
ENTER
INDEFINITE
OR TIMED
HOLD MODE
SET CURRENT
DAY AND TIME
SET CURRENT OR
PROGRAM DAY
CHANGE BETWEEN
DAYLIGHT SAVINGS
AND STANDARD TIME
INCREASE TIME SETTING
OR SCROLL FORWARD
THROUGH INSTALLER
SETUP AND SELF-TEST
DECREASE TIME SETTING
OR SCROLL BACKWARD
THROUGH INSTALLER
SETUP AND SELF-TEST
COPY ONE PROGRAMMED
DAY TO ANOTHER DAY
SET WAKE TIMES
AND SETPOINTS
CHANGE BETWEEN
HEATING AND COOLING
SETPOINTS
SET LEAVE TIMES
AND SETPOINTS
SET RETURN TIMES
AND SETPOINTS
SET SLEEP
TIMES AND
SETPOINTS
SELECT SYSTEM
OPERATION
SELECT FAN
OPERATION
M10675
TWO LED
INDICATORS
Fig. 8. LEDs location.